首页> 外文期刊>Journal of Technical Physics >Investigation of new cerenkov-type detectors for studies of fast electron beams emitted from hot plasma
【24h】

Investigation of new cerenkov-type detectors for studies of fast electron beams emitted from hot plasma

机译:用于研究热等离子体发射的快速电子束的新型切伦科夫型探测器的研究

获取原文
获取原文并翻译 | 示例
       

摘要

The paper describes a design and tests of a new diagnostic system, based on the application of Cerenkov- type detectors made of different materials. The use of radiators made of diamond and rutile makes it possible to reduce the electron energy threshold down to 51 keV and 33 keV, respectively. For the selection of absorption filters and calculation of initial energy spectra of the measured electron beams, a simple computer program is used. The paper presents some examples of time-resolved measurements of pulsed electron beams emitted form a PF-type facility, as performed by means of multi-channel Cerenkov-type detector heads. Some limitations of the technique applied are also discussed.
机译:本文基于由不同材料制成的切伦科夫型探测器的应用,描述了一种新型诊断系统的设计和测试。使用由金刚石和金红石制成的辐射器可以将电子能量阈值分别降低至51 keV和33 keV。为了选择吸收滤光片和计算被测电子束的初始能谱,使用了一个简单的计算机程序。本文介绍了通过多通道切伦科夫型探测器头对从PF型设备发射的脉冲电子束进行时间分辨测量的一些示例。还讨论了所应用技术的一些局限性。