首页> 外文期刊>Journal of structural engineering >Behavior of Steel Beam-to-Column Joints at Elevated Temperature: Experimental Investigation
【24h】

Behavior of Steel Beam-to-Column Joints at Elevated Temperature: Experimental Investigation

机译:钢梁柱节点在高温下的行为:实验研究

获取原文
获取原文并翻译 | 示例

摘要

Although beam-to-column joints are a critical part of steel and composite framed structures, very few tests have been conducted under fire conditions. Of the tests conducted, only a limited range of joint types has been studied. The main reason for this is the high cost associated with elevated-temperature tests. This paper presents the results of an experimental investigation of typical steel extended end-plate beam-to-column joints at elevated temperatures. Six beam-to-column joints were tested. These included three tests conducted at 400, 550, and 700℃, and another three tests on specimens at 700℃ with different axial compression forces applied to the beams to simulate restraint effects. Moment-rotation-temperature characteristics are summarized in order to investigate the degradation of this type of steel joint at elevated temperatures.
机译:尽管梁对柱节点是钢和复合框架结构的关键部分,但在着火条件下进行的测试很少。在进行的测试中,仅对有限范围的接头类型进行了研究。主要原因是与高温测试有关的高成本。本文介绍了在高温下典型的钢制延伸端板梁对柱节点的实验研究结果。测试了六个梁到柱的节点。其中包括在400、550和700℃下进行的三个测试,以及在700℃下对梁施加不同轴向压缩力以模拟约束效果的三个测试。为了研究这种类型的钢接头在高温下的退化,总结了矩-旋转-温度特性。