首页> 外文期刊>Journal of structural engineering >Performance Assessment of an Existing 47-Story High-Rise Building under Extreme Wind Loads
【24h】

Performance Assessment of an Existing 47-Story High-Rise Building under Extreme Wind Loads

机译:极端风荷载下现有47层高层建筑的性能评估

获取原文
获取原文并翻译 | 示例

摘要

This paper presents a wind performance-based evaluation of an existing 47-story steel moment frame high-rise building designed and built in the early 1970s according to the Houston Building Code in effect at the time with limited wind design criteria (strength requirement under factored wind loads, but no serviceability requirements considered) and no seismic design criteria. The building survived Hurricane Alicia (a Category-3 storm, 1983) without significant structural damage. The nonlinear dynamic response of the building to different wind hazard levels was evaluated by developing a 3D nonlinear finite-element model and using an incremental dynamic analysis (IDA) approach. Using results obtained from the IDA study and using wind performance criteria currently in practice, a wind performance assessment was carried out by evaluating the estimated performance levels as a function of basic wind speed. The results of this study indicated a surprisingly robust lateral capacity associated with the structural nonlinearity that occurred, but confirmed the existence of unacceptable serviceability performance under various levels of wind loading.
机译:本文介绍了根据当时的《休斯敦建筑规范》在当时有限的风力设计标准下有效设计和建造的现有47层钢制矩型框架高层建筑的基于风能的评估(强度要求已分解)风荷载,但未考虑可维护性要求)和抗震设计标准。该建筑物幸免于飓风“艾丽西亚”(1983年三级风暴)的影响,而没有重大的结构损坏。通过开发3D非线性有限元模型并使用增量动态分析(IDA)方法,评估了建筑物对不同风灾等级的非线性动力响应。使用从IDA研究中获得的结果并使用当前实践中的风力性能标准,通过评估作为基本风速函数的估算性能水平来进行风力性能评估。这项研究的结果表明,与所发生的结构非线性相关的横向能力出乎意料地强健,但证实了在不同水平的风荷载下,存在无法接受的使用性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号