...
首页> 外文期刊>Journal of Strength and Conditioning Research >RELIABILITY AND VALIDITY OF A PRESSURE ALGOMETER
【24h】

RELIABILITY AND VALIDITY OF A PRESSURE ALGOMETER

机译:压力计的可靠性和有效性

获取原文
获取原文并翻译 | 示例

摘要

Algometers are devices that can be used to identify the pressure and/or force eliciting a pressure-pain threshold. It has been noted in pressure-pain threshold studies that the rate at which manual force is applied should be consistent to provide the greatest reliability. This study tested the reliability and construct validity of an algometer (1000-Hz sampling rate) by manually applying pressure on a force plate (500-Hz sampling rate): 10 sets of 5 applications to 80 N and 1 set of 5 applications to each force level: 20, 30, 40, 50, 60, 70, 80, 90, 100, and 110 N. The investigator had previously become familiar with and practiced with the algometer. The handheld algometer had a 1-cm^sup 2^ round rubber application surface, and the maximum force reading was compared with maximum force readings by the force plate using SEM and t-tests. Force-time curves were analyzed for average slope representing rate of force application. Average Pearson (r) correlations between the maximum force reading of the algometer and force plate were excellent in both trials to 80 N (r = 0.990) and the incremental trials (r = 0.999). The application of force was reasonably constant, with slopes averaging 6.8 ± 0.932 N*s^sup -1^. The SEE was 0.323 N. In conclusion, with previous familiarization and practice, an investigator may have high reliability in the rate of force application. The device itself was also highly correlated with readings from a force plate and, therefore, may be considered valid. [PUBLICATION ABSTRACT]
机译:测力计是可用于识别引起压力痛阈值的压力和/或力的设备。在压力疼痛阈值研究中已经注意到,施加手动力的速率应保持一致,以提供最大的可靠性。本研究通过在测力板上手动施加压力(500 Hz采样率)来测试测力计(1000 Hz采样率)的可靠性和构造效度:10组,每组80 N施加5次,每组5次施加80 N力水平:20、30、40、50、60、70、80、90、100和110N。研究人员以前已经熟悉并实践了该血压计。手持式血压计具有一个1厘米2的圆形橡胶涂抹表面,并使用SEM和t检验将最大力读数与力板的最大力读数进行比较。分析了力时曲线的平均斜率,以表示力的施加率。在两个试验中,至80 N(r = 0.990)和增量试验(r = 0.999),测力计和力板的最大力读数之间的平均Pearson(r)相关性都非常好。施加的力是相当恒定的,斜率平均为6.8±0.932 N * s ^ sup -1 ^。 SEE为0.323N。总而言之,通过先前的熟悉和实践,调查人员可能会对力的施加速率具有高度的可靠性。设备本身也与测力板的读数高度相关,因此可以认为是有效的。 [出版物摘要]

著录项

  • 来源
    《Journal of Strength and Conditioning Research 》 |2009年第1期| p.312-314| 共3页
  • 作者单位

    ANN M. KINSER,1 WILLIAM A. SANDS,1 AND MICHAEL H. STONE21 Performance Services, United States Olympic Training Center, Colorado Springs, Colorado;

    and2 East Tennessee State University, Sports Performance Enhancement Consortium, Johnson City, TennesseeAddress correspondence to William A. Sands, bill.sands@usoc.org.23(1)/312-314Journal of Strength and Conditioning Research© 2009 National Strength and Conditioning Association;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号