...
首页> 外文期刊>Journal of South American earth sciences >Groundwater age dating using single and time-series data of environmental tritium in the Moeda Synclyne, Quadrilatero Ferrifero, Minas Gerais, Brazil
【24h】

Groundwater age dating using single and time-series data of environmental tritium in the Moeda Synclyne, Quadrilatero Ferrifero, Minas Gerais, Brazil

机译:地下室年龄在Moeda Synclyne,Quadrilatero Ferrifero,Minas Gerais,Brazil中使用单次和时间序列数据

获取原文
获取原文并翻译 | 示例

摘要

The use of tritium in the identification of the ?age? of groundwater is being used since the discovery of its potential for this purpose in 1954. The present work sought to apply and discuss the use of the different types of lumped parameter models (LPM) in the Caue? and Gandarela aquifers, in order to obtain the groundwater mean residence time based on tritium data. Water samples from several discharges related to the Caue? and Gandarela aquifers were collected during the month of September of 2017. The reconstruction of the historical series of tritium contents in the precipitation at the GNIP station CDTN-Belo Horizonte was carried out based on data from the Kaitoke (New Zealand) and Adelaide (Australia) stations in addition to the Brazilian stations Brasilia, Rio de Janeiro and Salvador. The sample results and the data of the reconstructed historical series of the tritium concentration in the CDTN station during the period between 1953 and 2017, served as the basis to use the lumped parameter models with the aid of the software TracerLPM, provided by the United States Geological Survey. From the overlap of some sample points with tritium samples collected in different years by different authors, an adjustment of some models of residence time distribution was possible. The models used were exponential (EM), exponential-piston (EPM), and dispersive (DM). The model that best fit to data was the EPM model. The mean transit time for the EPM model in the analyzed points varies from 63 to 95 years, with a median value of 73 years. Differences between values of the EPM ratio parameter were verified. However, all values indicate an exponential flow component greater than the piston flow component. The EPM model suggests a long retention time of the tracer in the aquifer system. It can be used as an approximation of the retention time for environmental contamination. The exponential model (EM) and piston flow model (PFM) were used together. Based on the data of a single tritium sample collected in time, and the average value of residence time provided by each model, a first approximation of the mean residence time value can be obtained. The results suggest that this is a better approximation than assuming a pure exponential model or piston flow model to describe the data of a single tritium sample in time as were made by previous local works. In general, a short residence time was estimated for the Caue? aquifer as a whole with some discharges with long residence time that drains regional flows from the deepest part of the Caue? aquifer, reflecting the complex structural geology fabric.
机译:在鉴定中使用氚?年龄?自1954年以来发现其潜力以来正在使用地下水。目前的作品试图申请和讨论在CAUE中使用不同类型的集总数模型(LPM)?和Gandarela含水层,以获得基于Tritium数据的地下水意味着停留时间。水样来自几个与caue有关的排放量?在2017年9月的月份收集了Gandarela含水层。基于来自Kaitoke(新西兰)和阿德莱德的数据,进行了Gnip站Cdtn-Belo Horizo​​ nte的降水中降水中的历史系列历史系列含量。(澳大利亚除了巴西站Brasilia,里约热内卢和萨尔瓦多外,车站在1953年至2017年期间CDTN站中CDTN站中氚浓度的样本结果和数据的数据,作为使用由美国提供的软件Tracerlpm的借助使用集总参数模型的基础地理调查。从不同年份收集的氚样品的一些样本的重叠从不同的作者收集的一些样本,可以调整某些型号的停留时间分布。使用的模型是指数(EM),指数 - 活塞(EPM)和分散(DM)。最适合数据的模型是EPM模型。 EPM模型在分析点中的平均转运时间从63到95年之间变化,中位数为73岁。验证了EPM比率参数的值之间的差异。然而,所有值表示大于活塞流量分量的指数流量分量。 EPM模型提示含水层系统中的示踪剂的长期保留时间。它可以用作环境污染的保留时间的近似。将指数模型(EM)和活塞流模型(PFM)一起使用。基于时间收集的单个氚样品的数据,以及每个模型提供的停留时间的平均值,可以获得平均停留时间值的第一近似。结果表明,这是比假设纯指数模型或活塞流模型更好地逼近,以便根据之前的本地工程制造的单个氚样品的数据。一般来说,估计了一个短暂的住宿时间为Caue?作为一个整体含水层,一些排放量长,停留时间从Caue的最深部分排出区域流动?含水层,反映复杂的结构地质面料。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号