首页> 外文期刊>Journal of Pressure Vessel Technology >Urea Reactor Integrity Evaluation Based on Failure Analysis
【24h】

Urea Reactor Integrity Evaluation Based on Failure Analysis

机译:基于失效分析的尿素反应堆完整性评价

获取原文
获取原文并翻译 | 示例
           

摘要

Multilayered pressure vessels tend to induce stress corrosion cracking (SCC) in the heavy weld. This conclusion is based on the recent ruptured urea reactor failure analysis. Finite element simulation proved that multilayered urea reactors have yielded zones at the heavy weld where the SCC crack initiated. Acoustic emission (AE) examination conducted for two in-service urea reactors revealed AE event clusters at the heavy weld and subsequent phased array reexamination confirmed the existence of propagating defects in the heavy weld. The results also showed that AE evaluation and phased array reexamination are sound combination methods to evaluate the integrity of multilayered urea reactors. Besides, they are superior to γ-ray inspection because of the uncertain propagation direction of SCC cracks.
机译:多层压力容器易于在重焊缝中引起应力腐蚀开裂(SCC)。该结论基于最近尿素反应器破裂的故障分析。有限元模拟证明,多层尿素反应器在重熔焊缝处产生了SCC裂纹产生的区域。对两个在役尿素反应堆进行的声发射(AE)检查显示,在重焊缝处有AE事件簇,随后的相控阵复查确认了在重焊缝中存在传播缺陷。结果还表明,AE评估和相控阵复检是评估多层尿素反应器完整性的合理组合方法。此外,由于SCC裂纹的传播方向不确定,它们优于γ射线检查。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号