首页> 外文期刊>Journal of Pipeline Systems Engineering and Practice >Acoustic Emission Leak Detection on a Metal Pipeline Buried in Sandy Soil
【24h】

Acoustic Emission Leak Detection on a Metal Pipeline Buried in Sandy Soil

机译:埋在沙土中的金属管道的声发射泄漏检测

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

An acoustic emission (AE) method was used to detect leaks and discern their location under flow conditions in a 304.8-m-long, 305-mm-diameter buried steel pipeline at the New Jersey Institute of Technology/U.S. Environmental Protection Agency (NJIT/USEPA) Buried Pipeline Test Facility in Edison, New Jersey. A 16.2 mL/s leak was successfully detected, and its discernible location was indicated to within 0.3 m, with a sensor separation of 65.5 m, and with water in the pipeline flowing at 11.4 L/s. Encouraging results were also obtained for a 1.3 mL/s leak that was discernible at a sensor separation of 21.3 m under the same flow conditions. Previous static pressure leak testing on this pipeline detected a 12.6 mL/s leak at sensor separations of up to 192.9 m, and it is expected that mitigating the effects of both externally produced and flow-induced background noise will allow for the detection of smaller leak rates under greater flow conditions. These results demonstrated that effective AE leak detection could be performed under flow conditions on water-filled buried metal pipelines in sandy soils.
机译:在新泽西州技术研究所/美国的304.8米长,直径305 mm的地下钢管道中,使用声发射(AE)方法检测泄漏并识别在流动条件下的泄漏位置。环境保护署(NJIT / USEPA)在新泽西州爱迪生市建造了管道测试设施。已成功检测到16.2 mL / s的泄漏,其可辨认的位置显示在0.3 m以内,传感器间距为65.5 m,并且管道中的水流量为11.4 L / s。在相同流量条件下,传感器间距为21.3 m时,也可看到1.3 mL / s的泄漏量,从而获得令人鼓舞的结果。先前在该管道上进行的静压泄漏测试在传感器间距最大192.9 m时检测到12.6 mL / s的泄漏,可以预期的是,减轻外部产生和流动引起的背景噪声的影响将允许检测较小的泄漏大流量条件下的流量。这些结果表明,在砂土中充水的埋藏金属管道中,在流动条件下可以进行有效的AE泄漏检测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号