首页> 外文期刊>Journal of nuclear science and technology >Density Wave Instability of Sodium Boiling Two-phase Flow in a Vertical Annulus at Low Pressure
【24h】

Density Wave Instability of Sodium Boiling Two-phase Flow in a Vertical Annulus at Low Pressure

机译:低压垂直环空中钠沸腾两相流的密度波不稳定性

获取原文
获取原文并翻译 | 示例

摘要

Experiments of density wave instability in a sodium boiling two-phase flow in an annulus were carried out with the parameters of heat flux from 80 to 976kW/m~2, inlet subcooling from 25.6 to 226.8℃, mass flow rate from 7.92 to 68.9 kg/h, and system pressure from 2,600 Pa to 0.06 MPa. It was found that the density wave instability occurred in the case of low exit quality, and the oscillation of flow rate was so large that the flow would be reversal. The lower inlet temperature, the higher system pressure and the larger mass flow rate could result in a more stable boiling two-phase flow. The oscillation period of the instability increased with the system pressure and the inlet subcooling, but it decreased with the mass flow rate. A correlation for the onset condition of the density wave instability was obtained from the experimental data.
机译:在环空的钠沸腾两相流中,热通量为80至976kW / m〜2,进口过冷度为25.6至226.8℃,质量流量为7.92至68.9 kg,进行密度波不稳定性实验。 / h,系统压力从2,600 Pa至0.06 MPa。发现在出口质量低的情况下发生密度波不稳定性,并且流量的振荡很大以至于流动将被逆转。较低的入口温度,较高的系统压力和较大的质量流量可能会导致更稳定的沸腾两相流。不稳定性的振荡周期随系统压力和入口过冷度而增加,但随质量流量而减小。从实验数据获得了与密度波不稳定性的开始条件的相关性。