This paper presents experimental results from a novel study to investigate the feasibility of using a dual sacrificial anode cathodic proteetion (SACP) system that combined corrosion protection with strengthening. A conductive polymer was used to bond the zinc plates to the concrete surface to form the SACP system, while a single unidirectional carbon fiber-reinforced polymer (CFRP) sheet was bonded to the zinc surface to provide strengthening. However, the aim was not to evaluate strengthening, but to determine if the CFRP interfered with the performance of the SACP system. Four concrete prisms, two of which were strengthened, were tested. The specimens were all placed in a high humidity environment, and their potential and galvanic current measurements were carried out over the entire 295-day exposure period. It was found that the SACP system performed adequately, although there was an apparent decrease in the protective current due to passivation of the zinc plate. Although the potential results from both SACP systems studied (bare Zn plate versus Zn+CFRP ply) were different, the current delivery was similar, indicating little interference between the Zn plate and the carbon fiber ply attached on top of this plate.
机译:本文介绍了一项新研究的实验结果,以研究使用将腐蚀防护与强化相结合的双牺牲阳极阴极保护(SACP)系统的可行性。使用导电聚合物将锌板粘结到混凝土表面上以形成SACP系统,同时将单向碳纤维增强聚合物(CFRP)单片粘结到锌表面上以提供增强作用。但是,其目的不是评估增强,而是确定CFRP是否干扰SACP系统的性能。测试了四个混凝土棱柱,其中两个进行了加固。将样品全部放置在高湿度环境中,并在整个295天的暴露时间内进行电势和电流的测量。已发现,尽管由于锌板的钝化而使保护电流明显降低,但SACP系统仍能正常工作。虽然两个SACP系统的潜在结果(裸露的Zn板与Zn + CFRP板)不同,但电流传输相似,这表明Zn板与附着在该板顶部的碳纤维板之间几乎没有干扰。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号