Benchmark of Discharge Calibration Methods for Submerged Sluice Gates

机译:淹没式水闸的排放标定方法基准

获取原文
获取原文并翻译 | 示例
           

摘要

Real accuracy of several calibration methods for sluice gates working in the submerged orifice flow condition was determined considering water discharge from water levels and gate openings. Data were taken from three gates of the same laboratory canal covering a large operational range. Using accurate hydraulic data, most of the methods produce errors of up to ± 10%. However, errors can rise up to ±40% with methods using typically recommended calibration values or constant discharge coefficients. The best results were obtained by a method based on dimensional analysis and the incomplete self-similarity theory proposed recently in the literature. Calibration with field data, in this case, produced errors not higher than ±3%. On the other side, when the gate discharge data are not available, the use of a contraction value of 0.611 within a good theoretical formulation gives very good results.
机译:考虑到水位和闸门开口的排水量,确定了在淹没孔口流量条件下的闸门的几种校准方法的实际精度。数据取自同一条实验室运河的三个闸门,覆盖范围广。使用准确的液压数据,大多数方法会产生高达±10%的误差。但是,使用通常推荐的校准值或恒定放电系数的方法,误差可能会上升至±40%。通过基于尺寸分析的方法和最近在文献中提出的不完全自相似理论,获得了最佳结果。在这种情况下,使用现场数据进行校准会产生不超过±3%的误差。另一方面,当栅极放电数据不可用时,在良好的理论公式内使用0.611的收缩值会产生非常好的结果。