A differential fiber Bragg grating strain sensor is developed, thereinto, the strain of a gage rod is translated into the deflection of the cantilever beam, on which the fiber Bragg gratings suffer the strain and shift their Bragg wavelengths. In this scheme, temperature compensation is achieved by the differential operation between the Bragg wavelength shifts of sensing gratings mounted on the top and bottom surfaces of the beam. The loading experiment indicates that the least-square linearity between the strain of the gage rod and the difference of the Bragg wavelength shifts of the sensing gratings is 0.3% in the range of the strain -1500 to 1500 με, the maximum error is 20 με, and the measure precision is 0.007. According to the flaws of the second lining of Shan Xin-Po Tunnel explored by the geological radar, these differential fiber Bragg grating strain sensors are installed on the lining. During the backfill period of 53 days and the operation period of 341 days, the strain survey results that the strains are related to the distribution of back cavity in the backfill period; however, the strains became gradually stable in the operation period.
机译:开发了差分光纤布拉格光栅应变传感器,其中,量规杆的应变转化为悬臂梁的偏转,在该悬臂梁上,光纤布拉格光栅承受应变并改变其布拉格波长。在该方案中,通过安装在光束顶面和底面的传感光栅的布拉格波长偏移之间的差分操作来实现温度补偿。加载实验表明,在应变-1500至1500με的范围内,量规杆的应变与传感光栅的布拉格波长位移​​的差之间的最小二乘线性为0.3%,最大误差为20με ,测量精度为0.007。根据地质雷达探测到的山心坡隧道第二衬砌的缺陷,将这些差分光纤布拉格光栅应变传感器安装在衬砌上。在53天的回填期和341天的运行期中,应变调查结果表明,应变与回填期中回孔的分布有关。但是,在运行期间,菌株逐渐趋于稳定。

著录项

  • 来源
  • 作者单位

    Faculty of Information Engineering and Automation Kunming University of Science and Technology, Kunming City, 650051, China Yunnan Aerospace Non-Destructive Evaluation Co., Kunming City, 650029, China;

    Yunnan Aerospace Non-Destructive Evaluation Co., Kunming City, 650029, China;

    Yunnan Aerospace Non-Destructive Evaluation Co., Kunming City, 650029, China;

    Faculty of Information Engineering and Automation Kunming University of Science and Technology, Kunming City, 650051, China;

    Faculty of Information Engineering and Automation Kunming University of Science and Technology, Kunming City, 650051, China;

    Faculty of Information Engineering and Automation Kunming University of Science and Technology, Kunming City, 650051, China;

    Faculty of Information Engineering and Automation Kunming University of Science and Technology, Kunming City, 650051, China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    fiber bragg grating strain sensor; gage rod; cantilever beam; tunnel; geological radar; back cavity; backfill;

    机译:光纤布拉格光栅应变传感器量规杆;悬臂梁隧道;地质雷达后腔回填;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号