Abstract The assessment of performance indices of a 3 MW utility-scale ground-mounted grid-tied solar farm located in Northern India is carried out in this work. Real-Time SCADA data of energy generation and other input parameters are utilized to evaluate performance indicators like Performance Ratio, Capacity Factor, efficiencies, losses, etc. The real-time and simulation results of the considered performance indicators are presented for the period from 1st January 2018 to 31st December 2018. The values of PR, CF and energy loss obtained are 80%, 16.35% and 19.42%, respectively. Among temperature, wind speed and level of accumulation of dust particles, ambient temperature is the most influential parameter that affects the PV performance in the considered region. The performance indicators estimated using PVSYST specifically for the detailed analysis of energy loss utilizing the three-stage conversion approach. The obtained estimated results are found to be in line with the actual values. These results could serve as a guideline for the application of solar PV in the northern part of India and in other countries with similar climatic conditions.
机译:摘要在印度北部的3兆瓦公用规模的地顶桥式太阳能电池绩效评估在这项工作中进行了。能量产生和其他输入参数的实时SCADA数据用于评估绩效比,容量因子,效率,损失等的性能指标等。在第1期的期间,所考虑的绩效指标的实时和仿真结果呈现出来的实时和仿真结果2018年1月至2018年12月31日。所获得的PR,CF和能量损失的价值分别为80%,16.35%和19.42%。温度,风速和粉尘颗粒的积累水平,环境温度是影响所考虑区域中的光伏性能的最有影响力的参数。使用PVSyst专门用于详细分析利用三阶段转换方法进行详细分析的性能指标。发现所获得的估计结果符合实际值。这些结果可以作为在印度北部和其他国家的北部应用太阳能光伏应用的指导方针。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号