Main objectives of the present paper to evaluate the removal of COD, TSS, TDS and oil and grease from the dairy industry wastewater by Electrocoagulation using iron as Monopolar configuration at different voltages and electrolysis time. The increase in voltage and electrolysis time increases the removal efficiency. For the removal of COD, TSS, TDS the optimum voltage and electrolysis time was 30V and 90 minutes for iron electrode. The percentage removal efficiency of 80.4%, 85.1%, 83.4% and obtained for the 30V. For oil and grease the removal efficiency of 91.4% was achieved at an optimum voltage and contact time of 30 V and 30 min. At the pH range of 4 to 7 the optimum removal efficiency of 86.5% of COD, 88% of TSS, 90.2 % of TDS and 94.5% of oil and grease was achieved with iron electrode. The removal efficiency decreases with increase in electrode spacing.
机译:本文的主要目的是评估在不同电压和电解时间下,以铁为单极性配置的电凝法,通过电凝从乳制品工业废水中去除COD,TSS,TDS和油脂。电压和电解时间的增加增加了去除效率。为了去除COD,TSS,TDS,铁电极的最佳电压和电解时间为30V,90分钟。对于30V,获得的百分比去除效率为80.4%,85.1%,83.4%。对于油脂,在最佳电压和30 V和30分钟的接触时间下,去除效率达到91.4%。在4至7的pH范围内,铁电极的最佳去除效率为86.5%的COD,88%的TSS,90.2%的TDS和94.5%的油脂。去除效率随着电极间隔的增加而降低。