Plasma-facing components for fusion reactors and other high heat flux heat sinks are subjected to a peripherally nonuniform heat flux. The monoblock test section under study is a single-side heated square cross-section heat sink with a circular coolant channel bored through the center. The heated length of the test section is 180 mm. The inside diameter and outside square sides are 10 mm and 30 mm, respectively. It was subjected to a constant heat flux on one side of the outside surfaces, and the remaining portion was not heated. The exit water subcooling varied from 55 to 101℃, the exit pressure was maintained at 0.207 MPa, and the mass velocity was 0.59 Mg/m~2 s. The results consist of three-dimensional wall temperature distributions and a display of two-dimensional quasi-boiling curves. These results are among the first full set of three-dimensional wall temperature measurements for a single-side heated monoblock flow channel which contains the effects of conjugate heat transfer for turbulent, subcooled flow boiling. In the single-phase region, good predictability resulted when the thermal hydraulic diameter was used.
机译:用于聚变反应堆和其他高热通量散热器的等离子组件受到周边不均匀的热通量的影响。正在研究的整体测试部分是一个单侧加热的方形横截面散热器,其中央有一个圆形的冷却剂通道。测试部分的加热长度为180毫米。内径和外侧正方形分别为10毫米和30毫米。在其外表面的一侧上使其受到恒定的热通量,其余部分未被加热。出口水过冷度从55℃变化到101℃,出口压力维持在0.207 MPa,质量速度为0.59 Mg / m〜2 s。结果包括三维壁温分布和二维准沸腾曲线显示。这些结果是单侧加热单块流道的第一个完整的三维壁温测量结果,其中包含共轭传热对湍流,过冷流沸腾的影响。在单相区域中,使用热工水力直径可获得良好的可预测性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号