The efficiency of asbestos stabilizers and their adaptability were evaluated by investigating the characteristics of asbestos fibers released from ceiling tiles. The impact of such variables as the wind speed or vibration conditions was also studied along with the asbestos stabilizers. The concentrations of the asbestos fibers released from damaged ceiling tiles treated with stabilizers decreased by 69.5-84.4% compared with those of untreated tiles for all variables, with a statistically significant difference (p<0.001). The effects of the environmental factors on the asbestos concentrations were analyzed through a multiple regression analysis. It was determined that the surface status of the ceiling tiles and stabilizers were the main factors affecting the concentration, and the reliability of these factors was estimated as 58.3%. The lengths of the chrysotile fibers released from the damaged ceiling tiles were in the range of 0.991-79.1 mu m for the untreated tiles and 3.74-35.6 mu m for the tiles treated with inorganic stabilizers. It was confirmed that inorganic stabilizers are more efficient for damaged ceiling tiles. The results of this study also show that the asbestos concentrations are greatly reduced after treating damaged ceiling tiles with a stabilizer. (C) 2015 Elsevier B.V. All rights reserved.
机译:通过研究从天花板释放的石棉纤维的特性,评估了石棉稳定剂的效率及其适应性。还与石棉稳定剂一起研究了诸如风速或振动条件等变量的影响。在所有变量下,与未处理的瓷砖相比,用稳定剂处理的受损天花板瓷砖释放的石棉纤维浓度降低了69.5-84.4%,具有统计学意义的差异(p <0.001)。通过多元回归分析分析了环境因素对石棉浓度的影响。确定天花板和稳定剂的表面状态是影响浓度的主要因素,这些因素的可靠性估计为58.3%。从受损的天花板砖释放的温石棉纤维的长度,未处理的砖的长度为0.991-79.1微米,而用无机稳定剂处理的砖的长度为3.74-35.6微米。证实了无机稳定剂对于损坏的天花板砖更有效。这项研究的结果还表明,用稳定剂处理受损的天花板后,石棉的浓度会大大降低。 (C)2015 Elsevier B.V.保留所有权利。

著录项

  • 来源
    《Journal of Hazardous Materials》 |2015年第30期|378-386|共9页
  • 作者单位

    Natl Inst Environm Res, Indoor Environm & Noise Res Div, Inchon 404708, South Korea|Catholic Univ Korea, Grad Sch, Dept Publ Hlth, Seoul 137701, South Korea;

    Natl Inst Environm Res, Global Environm Res Div, Inchon 404708, South Korea;

    Natl Inst Environm Res, Indoor Environm & Noise Res Div, Inchon 404708, South Korea;

    Natl Inst Environm Res, Indoor Environm & Noise Res Div, Inchon 404708, South Korea;

    Natl Inst Environm Res, Wonju Reg Environm Off, Wonju 220170, Gangwon Do, South Korea;

    Catholic Univ Korea, Coll Med, Dept Prevent Med, Seoul 137701, South Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Asbestos; Asbestos stabilizer; Ceiling tile; Wind speed; Vibration;