首页> 外文期刊>Journal of Hazardous Materials >Comparison of two standard test methods for determining explosion limits of gases at atmospheric conditions
【24h】

Comparison of two standard test methods for determining explosion limits of gases at atmospheric conditions

机译:确定大气条件下气体爆炸极限的两种标准测试方法的比较

获取原文
获取原文并翻译 | 示例
       

摘要

A comparison is made between two internationally accepted methods to determine the explosion limits of gases at atmospheric pressure and room temperature (20 l sphere -- DIN 5l649). Significant differences (about l vol./100) in the upper explosion limits (UEL) values are found for four hydrocarbons tested. A new criterion is proposed which leads to close agreement between the UEL values obtained by the two methods.
机译:在确定大气压力和室温下的气体爆炸极限(20 l球面-DIN 5l649)的两种国际公认方法之间进行了比较。发现所测试的四种烃的爆炸上限(UEL)值存在显着差异(约l vol./100)。提出了一种新的准则,该准则导致通过两种方法获得的UEL值之间的一致性。