首页> 外文期刊>Journal of Fusion Energy >Experimental Verification of Modified Lee's Model Using a Newly Designed and Constructed Filippov-Type Plasma Focus Device
【24h】

Experimental Verification of Modified Lee's Model Using a Newly Designed and Constructed Filippov-Type Plasma Focus Device

机译:使用新型设计和制造的Filippov型等离子聚焦装置对改良的Lee模型进行实验验证

获取原文
获取原文并翻译 | 示例
       

摘要

A new 20 kJ Filippov-type plasma focus device has been designed and constructed in Isfahan University. The paper reports on the design and construction of the Iranian Filippov-type plasma focus device (UIPFF1) using modified Lee's model. A Rogowski coil has been used to measure the experimental discharge current. Equivalent electric circuit of the device is RLC circuit; therefore the discharge current has a sinusoidal shape which its amplitude decreases exponentially during the time. The current signal contains a set of data from physical processes in the device as well as discharge current characteristics. In a typical discharge experiment these values were obtained: the discharge current was 181 kA, period of current signal 7.9 us, the total inductance of the device 132 nH and electrical resistance of the circuit 77 mΩ. By averaging from data obtained with a set of five experiments the calibration factor was obtained 121 kA/V. Temporal changes in plasma focus discharge current, confirmed the occurrence of pinch at a specific pressure of argon, neon and nitrogen gases. UIPFF1 has been tested between 15 and 25 kV and wide range of pressure for various gases. Experiments at various pressures and voltages have also confirmed reproducibility and stability of the plasma focus device.
机译:伊斯法罕大学已经设计和制造了一种新型的20 kJ Filippov型等离子体聚焦装置。该论文报道了使用改良的李氏模型设计和构造伊朗Filippov型等离子体聚焦装置(UIPFF1)。 Rogowski线圈已用于测量实验放电电流。器件的等效电路为RLC电路;因此,放电电流具有正弦曲线形状,其幅度在这段时间内呈指数下降。电流信号包含来自设备物理过程的一组数据以及放电电流特性。在典型的放电实验中,获得了以下这些值:放电电流为181 kA,电流信号周期为7.9 us,设备的总电感为132 nH,电路的电阻为77mΩ。通过对一组五个实验获得的数据进行平均,得出校准因子为121 kA / V。等离子体聚焦放电电流的时间变化证实了在氩,氖和氮气的特定压力下会发生收缩。 UIPFF1已在15到25 kV之间的压力下进行了测试,并在各种气体的广泛压力范围内进行了测试。在各种压力和电压下的实验还证实了等离子体聚焦装置的可再现性和稳定性。

著录项

  • 来源
    《Journal of Fusion Energy》 |2014年第4期|351-359|共9页
  • 作者单位

    Department of Nuclear Engineering, Faculty of Advanced Sciences and Technologies, University of Isfahan, Isfahan, I. R. Iran;

    Department of Physics, Faculty of Science, University of Isfahan, 81747-73441 Isfahan, I. R. Iran;

    Department of Nuclear Engineering, Faculty of Advanced Sciences and Technologies, University of Isfahan, Isfahan, I. R. Iran;

    Department of Nuclear Engineering, Faculty of Advanced Sciences and Technologies, University of Isfahan, Isfahan, I. R. Iran;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Filippov; Plasma pinch; Fusion; ML model;

    机译:菲利波夫等离子捏融合ML模型;
  • 入库时间 2022-08-18 00:40:36

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号