The effects of using a neutralizer after applying antimicrobial treatments and the effect of time lapse between treatment application and subsequent recovery and enumeration of Escherichia coli O157:H7 and Salmonella were investigated in Valencia oranges. Inoculated oranges surfaces were washed with distilled water for 15 s and then sprayed with a solution containing 200 mg/liter sodium hypochlorite (pH 6.5) for 15 s; they were then dipped in L-lactic acid (2.0% at 55℃) for 1 min or in distilled water at 80℃ for 1 min. Posttreatment, oranges were divided into two groups. In the first group, oranges were dipped in neutralization treatment: 270 ml of buffered peptone water for 2 min for lactic acid-treated oranges, 270 ml of Dey-Engley broth for 2 min for chlorine-treated oranges, or 3.7 liters of tap water (25℃) for 10 s for hot water-treated oranges. The second group of treated oranges was not subjected to any neutralizer. All oranges then were kept at room temperature (average 26.2℃) and sampled at 0, 7.5, and 15 min for enumeration of surviving Salmonella and E. coli O157:H7. The orange surface (30 cm~2) was excised for pathogen enumeration. The presence of free chlorine and changes in pH and temperature on the orange surface were determined in uninoculated, treated oranges. Free chlorine was detected on oranges after treatment; the change in temperature of orange surfaces was greater during treatment with hot water than with lactic acid. Nevertheless, pathogen enumeration did not show any impact of neutralizer use on the residual activity of antimicrobials or any impact of the time elapsed between antimicrobial treatment and recovery of bacterial pathogens from inoculated oranges (P ≥ 0.05). The results of this study indicate that the lack of a neutralizing step before enumeration of pathogens is not likely to affect the accuracy of results during challenge studies to test pathogen reduction strategies on oranges.
机译:在瓦伦西亚橘子中研究了在进行抗菌处理后使用中和剂的效果以及在应用抗菌剂与随后的大肠杆菌O157:H7和沙门氏菌回收和计数之间的时间间隔的影响。接种过的橙子表面用蒸馏水洗涤15 s,然后喷洒含有200 mg / l次氯酸钠(pH 6.5)的溶液15 s;然后将它们浸入L-乳酸(55℃时为2.0%)中1分钟或浸入80℃的蒸馏水中中1分钟。治疗后,橘子分为两组。在第一组中,将橙子浸泡在中和处理中:270 ml的缓冲蛋白ept水用于乳酸处理的橙子2分钟,270 ml的Dey-Engley肉汤用于氯处理的橙子2分钟,或3.7升自来水(25℃)10秒钟,用于热水处理过的橙子。第二组处理过的橙子未进行任何中和。然后将所有橙子都保持在室温(平均26.2℃)下,并在0、7.5和15分钟取样,以对存活的沙门氏菌和大肠杆菌O157:H7进行计数。切下橙色表面(30 cm〜2)以进行病原体计数。在未接种,处理过的橙子中测定了游离氯的存在以及橙子表面的pH和温度的变化。处理后在橙子上检测到游离氯;与热水相比,用热水处理时橙色表面的温度变化更大。然而,病原体计数并未显示使用中和剂对抗菌剂的残留活性有任何影响,也没有显示抗菌剂处理与从接种橘子中恢复细菌病原体之间经过的时间之间的任何影响(P≥0.05)。这项研究的结果表明,在列举病原体之前缺少中和步骤不太可能会影响挑战测试研究橙子病原体减少策略的结果的准确性。

著录项

  • 来源
    《Journal of food protection 》 |2013年第2期| 328-332| 共5页
  • 作者单位

    Departamento de Farmacobiologia, Universidad de Guadalajara, Guadalajara, Jalisco 44430, Mexico;

    Departamento de Farmacobiologia, Universidad de Guadalajara, Guadalajara, Jalisco 44430, Mexico;

    Departamento de Farmacobiologia, Universidad de Guadalajara, Guadalajara, Jalisco 44430, Mexico;

    Departamento de Farmacobiologia, Universidad de Guadalajara, Guadalajara, Jalisco 44430, Mexico;

    Department of Animal Science,Texas A&M University, College Station, Texas 77843-2471, USA;

    Departamento de Farmacobiologia, Universidad de Guadalajara, Guadalajara, Jalisco 44430, Mexico;

    Department of Animal Science,Texas A&M University, College Station, Texas 77843-2471, USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号