This article is a guide for sprinkler contractors, facilities managers, and their technical advisors who sometimes have to deal with the consequences of iron-water corrosion inside pressurized, low-carbon steel fire protection systems that contain water. The consequences include: (1) pinhole leaks and (2) build-up of insoluble corrosion residues on the interior pipe wall that increases pipe friction losses. A reference is made to sections of the National Fire Codes/NFPA 13 that address pipe materials, protection of steel piping against corrosion, and pipe friction losses. Electrochemical metal-water corrosion processes that can occur inside pressurized, low-carbon steel fire protection systems that contain water are discussed, as is microbiologically influenced corrosion. Corrosion control measures arising from the electrochemical science underlying both metal-water corrosion and microbiologically influenced corrosion are suggested.
机译:本文为洒水承包商,设施管理员及其技术顾问提供指南,这些承包商有时不得不处理在装有水的加压低碳钢消防系统中铁水腐蚀的后果。其后果包括:(1)针孔泄漏;(2)在内管壁上积聚不溶的腐蚀残留物,这会增加管道的摩擦损失。请参考《国家消防法规/ NFPA 13》中涉及管道材料,保护钢管免受腐蚀以及管道摩擦损失的部分。讨论了可能在含水的加压低碳钢消防系统内部发生的电化学金属-水腐蚀过程,以及受微生物影响的腐蚀过程。建议了基于电化学科学的腐蚀控制措施,这些腐蚀科学既是金属水腐蚀又是微生物影响的腐蚀。