...
首页> 外文期刊>Journal of Experimental Marine Biology and Ecology >Performance of absorption coefficient measurements for the in situ determination of chlorophyll-a and total suspended matter
【24h】

Performance of absorption coefficient measurements for the in situ determination of chlorophyll-a and total suspended matter

机译:用于原位测定叶绿素a和总悬浮物的吸收系数测量

获取原文
获取原文并翻译 | 示例
           

摘要

The concentrations of chlorophyll-a ([chl-a]) and total suspended matter ([TSM]) are important parameters in biological oceanography. [Chl-a] is a commonly used proxy for estimating phytoplankton biomass while [TSM] also includes detrital material and mineral particles and thus influences light attenuation and photosynthetic activity in the water columa For characterizing the distribution (patchiness) of both parameters adequately over a longer time period, fast and effective measurement methods are required that can also be applied in situ or continuously. Thus, alternatively to direct determination of [chl-a] and [TSM], optical proxy values are often measured. The PSICAM is an integrating cavity approach for measuring absorption coefficients of water constituents with high precision which can be used also continuously (flow-through-PSICAM). In this study, the performance of these absorption measurements for [chl-a] and [TSM] determination was evaluated and compared with the performance of traditional approaches using chl-a fluorescence and turbidity measurements. Data were collected in the German Bight (North Sea) in 2010 and 2011. For [chl-a], fluorescence measurements are compared with pigment absorption coefficient values at a wavelength of 676 nm (a_(Φ 676 nm)). while the [TSM]-proxies were turbidity and particle absorption at 700 nm (a_(p 700 nm)). As reference data, HPLC-determined [chl-a] and gravimetrically determined [TSM] were used. Our results showed linear relationships between [chl-a] and fluorescence or a_(Φ 676 nm). respectively. Coefficients of determination (R~2) were in a range of 0.71 to 0.88, with the higher values related to the absorption measurements. Furthermore, it was demonstrated that fluorescence underestimates [chl-a] depending on ambient pho-tosynthetically active radiation (PAR). Linear relationships were also observed between [TSM] and its optical proxies with R~2 values between 0.93 and 0.98. Turbidity measurements appeared to be influenced to a certain extent by the physical properties of the suspended material, resulting in a slightly higher variability than the a_(p 700 nm) measurements. Absorption measurements turned out to be promising optical proxies for determining [TSM] and [chl-a] due to their lower variability compared with the other proxies. This improved accuracy could be already partially achieved also for continuous measurements. Moreover, a combination of the different optical methods has the potential to provide additional information besides concentration, such as the source of TSM in the water or physiological condition of the phytoplankton.
机译:叶绿素-a([chl-a])和总悬浮物([TSM])的浓度是生物海洋学中的重要参数。 [Chl-a]是估算浮游植物生物量的常用替代方法,而[TSM]还包括碎屑物质和矿物质颗粒,因此会影响水气垫中的光衰减和光合活性。较长的时间,需要快速有效的测量方法,这些方法也可以原位或连续使用。因此,替代直接确定[ch1-a]和[TSM],经常测量光学代理值。 PSICAM是一种积分腔方法,可以高精度测量水成分的吸收系数,该方法也可以连续使用(流通PSICAM)。在这项研究中,对[chl-a]和[TSM]测定的这些吸收测量的性能进行了评估,并与使用chl-a荧光和浊度测量的传统方法的性能进行了比较。在2010年和2011年在德国湾(北海)收集了数据。对于[chl-a],将荧光测量值与波长为676 nm(a_(Φ676 nm))的色素吸收系数值进行比较。而[TSM]代理则是浊度和700 nm(a_(p 700 nm))的颗粒吸收。作为参考数据,使用HPLC测定的[chl-a]和重量测定的[TSM]。我们的结果表明[chl-a]与荧光或a_(Φ676 nm)之间呈线性关系。分别。测定系数(R〜2)在0.71至0.88的范围内,较高的值与吸收测量有关。此外,已证明荧光低估了[chl-a],具体取决于周围的光合作用活性辐射(PAR)。还观察到[TSM]与其光学代理之间的线性关系,R〜2值在0.93至0.98之间。浊度测量值似乎在一定程度上受悬浮材料的物理性能的影响,导致变异性比a_(p 700 nm)测量值稍高。由于与其他代理相比,它们的可变性较低,因此吸收测量结果是确定[TSM]和[chl-a]的光学代理。对于连续测量,已经可以部分实现这种提高的精度。此外,将不同的光学方法结合使用还可以提供除浓度以外的其他信息,例如水中TSM的来源或浮游植物的生理状况。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号