Gas and liquid mass transfer in a bubble column with porous ceramic gas distributor was investigated. The porous ceramic disc of our self-made was used as a gas distributor to compare with commercial products made of sintered glasses. The volumetric gas-liquid mass transfer coefficient was determined by the dynamic method. We found that the volumetric mass transfer coefficient (k_L a) measured from our discs is higher than that of commercial product, especially in the low gas flux region (Ug<1 cm/sec). Experimental results showed that the volumetric mass transfer coefficient was significantly effective in pore size of the gas distributor. The k_L a value decreased with increasing pore size of a distributor.
机译:研究了带有多孔陶瓷气体分配器的鼓泡塔中的气体和液体传质。我们将自制的多孔陶瓷圆盘用作气体分配器,以与由烧结玻璃制成的商业产品进行比较。气液传质系数通过动力学方法确定。我们发现,从我们的圆盘测得的体积传质系数(k_L a)高于商品,尤其是在低气体通量区域(Ug <1 cm / sec)。实验结果表明,体积传质系数在气体分配器的孔径方面显着有效。 k_L a值随着分配器孔径的增加而减小。