Cryptosporidium is an extremely virulent microorganism; contamination of water works systems by Cryptosporidium oocysts is a serious issue in public health. However, a great deal of effort is required to detect oocysts in source water for drinking, because the oocysts have to be concentrated from a large volume of water before detection. In this study, the concentration of oocysts in oocyst-polluted artificial river water was examined by coagulation and foam separation. The oocysts concentrated in the foam water were purified using immunomagnetic separation and assessed using epifluorescence microscopy. When ferric coagulation was performed prior to foam separation, oocysts were effectively removed from the river water and concentrated in the foam within 10min. The removal efficiency was greater than 96% at the optimum iron and casein concentrations of 5mg-Fe L-1 and 20mg L-1, respectively. Furthermore, the number of recovered oocysts in the solution obtained by the dissolution of the collected ferric flocs from foam water was the same as that obtained using the Japanese standard procedure for detection of Cryptosporidium in water using membrane filtration. This is a novel method of concentrating Cryptosporidium oocysts for detection in river water using a coagulation and foam separation combined with acid dissolution of ferric flocs; the method is easy to use, rapid, and efficient.
机译:隐孢子虫是一种剧毒微生物。隐孢子虫卵囊对供水系统的污染是公共卫生中的一个严重问题。但是,要检测饮用水中的卵囊,需要付出很大的努力,因为卵囊必须在检测之前从大量的水中浓缩。在这项研究中,通过凝结和泡沫分离检测了被卵囊污染的人工河水中卵囊的浓度。使用免疫磁分离法纯化浓缩在泡沫水中的卵囊,并使用落射荧光显微镜进行评估。当在泡沫分离之前进行铁凝结时,将卵囊有效地从河水中去除,并在10分钟内浓缩在泡沫中。在最佳铁和酪蛋白浓度分别为5mg-Fe L-1和20mg L-1时,去除效率大于96%。此外,通过从泡沫水中溶解收集的铁絮状物而获得的溶液中回收的卵囊的数量与使用日本标准程序通过膜过滤检测水中隐孢子虫的方法相同。这是一种浓缩的隐孢子虫卵囊,用于凝结和泡沫分离结合酸絮凝的三价铁絮凝物,用于河水中的检测;该方法易于使用,快速且高效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号