摘要

The paper reports a new rapid radioanalytical procedure for the determination of plutonium (Pu) in sediments by solid phase extraction chromatography (SPEC) using Bis-(2-ethylhexyl) carbamoyl methoxy phenoxy-bis-(2ethylhexyl) grafted resin, abbreviated as Benzodioxodiamide (BenzoDODA) grafted resin. The resin was synthesized and evaluated for its sorption behaviour towards Pu in batch and column mode to determine its efficacy for selective recovery of Pu from sediment samples. The analytical procedure was based on the radiochemical separation of samples by acid digestion, followed by preconcentration of actinides by co-precipitation with Fe (OH)3 and finally selective recovery of Pu by SPEC using a column filled with BenzoDODA grafted resin. Pu was then radiometrically assayed by preparing alpha disc sources with electro-deposition followed by alpha spectrometry. The method was further validated with IAEA reference materials. This method gives reliable and reproducible results for the activity concentration of Pu in sediment samples within 24 h.
机译:本文通过使用双(2-乙基己基)氨基甲氧基苯氧基 - 双 - (2甲基己基)接枝树脂,通过固相萃取色谱(SPED)在沉积物中测定沉积物中的钚(PU)进行了新的快速放射性学程序。缩写为苯二氧胺(苯代达植物树脂。合成树脂并评估其对PU的吸附行为,分批和柱模式,以确定其从沉积物样品中选择性恢复PU的功效。分析程序基于酸消化的样品的放射化学分离,然后通过用Fe(OH)3共沉淀,通过用填充有苯并二滴水树脂填充的柱,通过Fe(OH)3来选择性回收PU的前浓度。然后通过用电沉积制备α盘源,然后α光谱法测定PU。通过IAEA参考材料进一步验证该方法。该方法为24小时内的沉积物样品中PU的活性浓度提供可靠和可再现的结果。

著录项

  • 来源
    《Journal of Environmental Radioactivity》 |2021年第8期|106620.1-106620.6|共6页
  • 作者单位

    Bhabha Atom Reseach Ctr Radiat Safety Syst Div Mumbai 400085 Maharashtra India|Homi Bhabha Natl Inst Mumbai 400085 Maharashtra India;

    Bhabha Atom Res Ctr Mat Proc & Corros Engn Div Mumbai 400085 Maharashtra India|Homi Bhabha Natl Inst Mumbai 400085 Maharashtra India;

    Bhabha Atom Res Ctr Mat Proc & Corros Engn Div Mumbai 400085 Maharashtra India;

    Bhabha Atom Reseach Ctr Radiat Safety Syst Div Mumbai 400085 Maharashtra India;

    Bhabha Atom Res Ctr Mat Proc & Corros Engn Div Mumbai 400085 Maharashtra India;

    Bhabha Atom Reseach Ctr Radiat Safety Syst Div Mumbai 400085 Maharashtra India;

    Bhabha Atom Res Ctr Environm Monitoring & Assessment Div Mumbai 400085 Maharashtra India;

    Bhabha Atom Res Ctr Mat Proc & Corros Engn Div Mumbai 400085 Maharashtra India;

    Homi Bhabha Natl Inst Mumbai 400085 Maharashtra India;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    BenzoDODA grafted resin; Plutonium; Extraction chromatography; Alpha spectrometry; SPEC; Sediments;

    机译:Benzododa接枝树脂;钚;提取色谱;α光谱;规格;沉积物;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号