首页> 外文期刊>Journal of Environmental Radioactivity >Environmental radon studies using solid state nuclear track detectors
【24h】

Environmental radon studies using solid state nuclear track detectors

机译:使用固态核径迹探测器进行环境ra研究

获取原文
获取原文并翻译 | 示例
       

摘要

The results of radon activity recorded in 70 dwellings of Nurpur area, Kangra district, Himachal Pradesh, India are reported. LR-115 Type 2 films in the bare mode were exposed for four seasons of three months each covering a period of one year for the measurement of indoor radon levels. The calibration constant of 0.020 tracks cm~(-2) d~(-1) per Bq m~(-3) has been used to express radon activity in Bq m~(-3). The annual average indoor radon concentrations in 17 different villages of the area are found to vary from 168 ± 46 to 429 ± 71 Bq m~(-3). Most of the indoor radon values lie in the range of action levels (200-600 Bq m~(-3)) recommended by International Commission on Radiological Protection.
机译:据报道,在印度喜马al尔邦Kangra地区的Nurpur地区的70户住宅中记录了ra活动的结果。将裸露模式的LR-115 2型胶片曝光三个月四个季节,每个季节覆盖一年,以测量室内ra水平。每Bq m〜(-3)的校准常数为0.020轨cm〜(-2)d〜(-1),用于表示Bq m〜(-3)中的ra活度。该地区17个不同村庄的年平均室内ra浓度在168±46至429±71 Bq m〜(-3)之间变化。大多数室内ra值在国际放射防护委员会建议的作用水平范围内(200-600 Bq m〜(-3))。