首页> 外文期刊>Journal of Environmental Management >A comparative study of the treatment of ethylene plant spent caustic by neutralization and classical and advanced oxidation
【24h】

A comparative study of the treatment of ethylene plant spent caustic by neutralization and classical and advanced oxidation

机译:中和,经典和高级氧化处理乙烯装置废碱的比较研究

获取原文
获取原文并翻译 | 示例
           

摘要

The treatment of spent caustic produced from an ethylene plant was investigated. In the case of neutralization alone it was found that the maximum removal of sulfide was at pH values below 5.5. The higher percentage removal of sulfides (99% at pH = 1.5) was accompanied with the highest COD removal (88%). For classical oxidation using H_2O_2 the maximum COD removal percentage reached 89% at pH = 2.5 and at a hydrogen peroxide concentration of 19 mM/L For the advanced oxidation using Fenton's process it was found that the maximum COD removal of 96.5% was achieved at a hydrogen peroxide/ferrous sulfate ratio of (7:1).
机译:研究了乙烯厂生产的废苛性碱的处理方法。仅在中和的情况下,发现硫化物的最大去除是在低于5.5的pH值下。较高的硫化物去除率(pH = 1.5时为99%)伴随着最高的COD去除率(88%)。对于使用H_2O_2进行的经典氧化,在pH = 2.5且过氧化氢浓度为19 mM / L时,最大COD去除率达到89%。对于使用Fenton法进行的高级氧化,发现在90°C时最大COD去除率为96.5%。过氧化氢/硫酸亚铁比例为(7:1)。