首页> 外文期刊>Journal of Engineering for Gas Turbines and Power >Experimental Study on Fault Caused by Partial Arc Steam Forces and Its Economic Solution
【24h】

Experimental Study on Fault Caused by Partial Arc Steam Forces and Its Economic Solution

机译:部分电弧蒸汽力引起的故障的试验研究及经济解决方案

获取原文
获取原文并翻译 | 示例

摘要

It is noticed in a few steam turbines that there are a pad temperature rise of more than 10℃ and a radial journal movement of more than 50 μm in the bearings adjacent to control stage when they operate under partial arc admission at 60-80% of their full load. It is found through fault mechanism analysis and experimental study that the fault is caused by partial arc steam forces acting on control stage. A fault characteristic is concluded to help identify this fault. Diagonal admission is therefore proposed as an economic solution for elimination of this fault and it is proved to be effective through practical test.
机译:在一些汽轮机中,当轴承在部分电弧允许的60%至80%的条件下运行时,在与控制级相邻的轴承中,轴瓦温度升高超过10℃,径向轴颈运动超过50μm。他们的满负荷。通过故障机理分析和实验研究发现,故障是由作用在控制级上的部分电弧蒸汽力引起的。总结故障特征以帮助识别该故障。因此,建议采用对角线进入作为消除该故障的经济解决方案,并通过实际测试证明是有效的。