首页> 外文期刊>Journal of Engineering for Gas Turbines and Power >Erratum: 'Air/Water Counter-Current Flow Experiments in a Model of the Hot Leg of a Pressurized Water Reactor'[Journal of Engineering for Gas Turbines and Power, 2009,131(2), p. 022905]
【24h】

Erratum: 'Air/Water Counter-Current Flow Experiments in a Model of the Hot Leg of a Pressurized Water Reactor'[Journal of Engineering for Gas Turbines and Power, 2009,131(2), p. 022905]

机译:勘误表:“在压水堆热腿模型中的空气/水逆流实验” [燃气轮机与动力工程学报,2009,131(2),p。 022905]

获取原文
获取原文并翻译 | 示例
       

摘要

An error in the implementation into the test facility of the air flow meter used during the experiments was noticed after publication of the paper. As a consequence, the raw flow rates recorded by the digital data acquisition system with this flow meter are wrong. In order to correct the measured flow rates, a calibration curve was recorded with a certified rotameter. The obtained calibration points could be correlated in order to obtain the correction function applied to the raw measuring values. This resulted in the following modifications compared to the original paper:
机译:发表论文后,发现在实验过程中使用的空气流量计在测试设备中的实现存在错误。结果,用该流量计由数字数据采集系统记录的原始流速是错误的。为了校正测得的流速,用合格的转子流量计记录校准曲线。可以将获得的校准点关联起来,以获得应用于原始测量值的校正函数。与原始论文相比,进行了以下修改:

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号