Land-based power units have to fulfill even more high levels of production and reliability. In harsh environments (desert and tropical installations, typically), the power unit ingests high amounts of dust that might deposit inside the compressor. In this paper, the analysis of a multistage compressor performance that operates under sandy and humid conditions has been assessed. The compressor units, which equips the Allison 250 C18 compressor, has been subjected to multiple runs under severe conditions of soil dust ingestion. The compressor has been operated according to subsequent runs, and at the end of each run, the performance curve was recorded; the performance losses, in terms of pressure ratio, have been measured during the operations. The characteristic curve of each run is representative of the level of contamination of the unit. Finally, the compressor has been washed, and the performance curve, in the recovered conditions, has been recorded. The results show the modification and the downward shift of the characteristic curves which lead to a gradual loss of the compressor performance. The curves realized after dust ingestion have been compared with the recovered curve after online washing. The measurement shows a promising recovery of the performances, even if the compressor flow path appears affected by localized deposits able to resist to the droplet removal action. Detailed photographic reports of the inlet guide vane (IGV) and the first compressor stages have been included in this analysis. After each run, the IGV, the rotor blade and stator vane of the first stage, and the hub and the shroud surfaces have been photographed. The pictures show the deposition patterns on the blades and the compressor surfaces. The comparison of the pictures of the internal surfaces, before and after the washing, highlights the parts that are more critical to clean and needy of attention during offline washing and overhaul.
机译:陆基电力装置必须满足更高的生产和可靠性。在恶劣环境(沙漠和热带设施,通常)中,电源单元摄取可能在压缩机内部沉积的大量灰尘。在本文中,评估了在砂质和潮湿条件下运行的多级压缩机性能的分析。压缩机单元配备Allison 250 C18压缩机,在土壤尘埃的严重条件下经受多次运行。根据后续运行操作,并且在每次运行结束时,记录了性能曲线;在经营期间测量了压力比的性能损失。每个运行的特征曲线代表该单元的污染水平。最后,已经清洗了压缩机,并记录了回收的条件下的性能曲线。结果显示了特征曲线的修改和向下偏移,这导致压缩机性能的逐渐丧失。在在线洗涤后与恢复的曲线进行了比较后实现的曲线。测量表明,即使压缩机流动路径出现的局部沉积物,能够抵抗液滴去除动作,也显示了性能的有望恢复。在该分析中包括详细的入口导向叶片(IGV)和第一压缩机阶段的摄影报告。在每个运行之后,已经拍摄了第一级的IGV,转子叶片和定子叶片和毂和护罩表面。图片显示刀片上的沉积图案和压缩机表面。内部表面,洗涤前后的图片的比较突出了在离线洗涤和大修期间清洁和需要注意的零件。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号