首页> 外文期刊>Journal of Electronic Packaging >Pressure Drop of Impingement Air Cooled Plate Fin Heat Sinks
【24h】

Pressure Drop of Impingement Air Cooled Plate Fin Heat Sinks

机译:冲击空气冷却板翅片散热器的压降

获取原文
获取原文并翻译 | 示例
           

摘要

The performance of impingement air cooled plate fin heat sinks differs significantly from that of parallel flow plate fin heat sinks. A simple impingement flow pressure drop model based on developing laminar flow in rectangular channels is proposed. The model is developed from simple momentum balance and utilizes fundamental solutions from fluid dynamics to predict its constitutive components. To test the validity of the model, experimental measurements of pressure drop are performed with heat sinks of various impingement inlet widths, fin spacings, fin heights, and airflow velocities. The accuracy of the pressure drop model was found to be within 20% of the experimental data taken on four heat sinks and other experimental data from the published literature at channel Reynolds numbers less than 1200. The simple model is suitable for impingement air cooled plate fin heat sinks parametric design studies.
机译:冲击空气冷却的板翅式散热器的性能与平行流板翅式散热器的性能明显不同。提出了一种基于矩形通道内层流发展的简单冲击流压降模型。该模型基于简单的动量平衡而开发,并利用流体动力学的基本解决方案来预测其组成成分。为了测试模型的有效性,使用各种冲击入口宽度,鳍片间距,鳍片高度和气流速度的散热器进行了压降的实验测量。发现压降模型的精度在四个散热器上获得的实验数据的准确性不超过20%,并且在通道雷诺数小于1200的情况下,也来自已发表文献的其他实验数据。该简单模型适用于冲击式风冷板翅片散热器参数设计研究。