In the last decades, particular attention has been paid to the seismic vulnerability of existing reinforced concrete buildings designed for gravity loads only. Such buildings, designed before the introduction of capacity design in modern seismic codes, are very common, particularly in seismic prone countries of the Mediterranean area. Due to poor detailing and lacking of capacity design principles, high vulnerability has been highlighted in several past studies. In this article, inadequate seismic response and peculiar damage pattern are investigated by means of shake table tests performed on a 1: 2 scaled 3-story infilled prototype. Particular attention is given to the role of beamcolumn joints and frame-panel interaction. The effectiveness of the EC8-based assessment approach is then evaluated; both linear and nonlinear numerical models, with different levels of sophistication, have been implemented in order to explore their behavioral aspects.
机译:在过去的几十年中,已经特别关注了仅用于重力载荷的现有钢筋混凝土建筑的地震脆弱性。在现代地震规范中引入容量设计之前设计的此类建筑物非常普遍,尤其是在地中海地区地震多发的国家。由于细节欠佳以及缺乏能力设计原则,因此在过去的几项研究中都强调了高度脆弱性。在本文中,通过对以1:2比例缩放的3层填充原型进行的振动台试验研究了不足的地震响应和特殊的破坏模式。特别注意梁柱节点和框架-面板相互作用的作用。然后评估基于EC8的评估方法的有效性;为了探索它们的行为方面,已经实施了具有不同复杂度的线性和非线性数值模型。