The objective of this study is to assess the impact on nodule detection and efficiency using a computer-aided detection (CAD) device seamlessly integrated into a commercially available picture archiving and communication system (PACS). Forty-eight consecutive low-dose thoracic computed tomography studies were retrospectively included from an ongoing multi-institutional screening study. CAD results were sent to PACS as a separate image series for each study. Five fellowship-trained thoracic radiologists interpreted each case first on contiguous 5 mm sections, then evaluated the CAD output series (with CAD marks on corresponding axial sections). The standard of reference was based on three-reader agreement with expert adjudication. The time to interpret CAD marking was automatically recorded. A total of 134 true-positive nodules, measuring 3 mm and larger were included in our study; with 85 ≥ 4 and 50 ≥ 5 mm in size. Readers detection improved significantly in each size category when using CAD, respectively, from 44 to 57 % for ≥3 mm, 48 to 61 % for ≥4 mm, and 44 to 60 % for ≥5 mm. CAD stand-alone sensitivity was 65, 68, and 66 % for nodules ≥3, ≥4, and ≥5 mm, respectively, with CAD significantly increasing the false positives for two readers only. The average time to interpret and annotate a CAD mark was 15.1 s, after localizing it in the original image series. The integration of CAD into PACS increases reader sensitivity with minimal impact on interpretation time and supports such implementation into daily clinical practice.
机译:这项研究的目的是使用计算机辅助检测(CAD)设备无缝集成到市售图片存档和通信系统(PACS)中,评估其对结节检测和效率的影响。一项正在进行的多机构筛查研究回顾性地纳入了48例连续的低剂量胸部计算机断层扫描研究。 CAD结果作为每个研究的单独图像系列发送到PACS。由五名经过研究金培训的胸腔放射科医生首先在连续的5毫米截面上解释每种情况,然后评估CAD输出序列(在相应的轴向截面上带有CAD标记)。参考标准是基于三级阅读者的同意和专家评审的。自动解释了CAD标记的时间。我们的研究中总共包括了134个3毫米及更大的真阳性结节。尺寸为85≥4和50≥5 mm。使用CAD时,在每个尺寸类别中,读取器的检测效果显着提高,≥3 mm分别从44%增至57%,≥4mm分别从48%增至61%,≥5mm则从44%增至60%。对于≥3,≥4和≥5mm的结节,CAD独立灵敏度分别为65%,68%和66%,而CAD仅显着增加了两个阅读器的假阳性率。将其定位在原始图像系列中后,解释和注释CAD标记的平均时间为15.1 s。将CAD集成到PACS中可以提高阅读器的敏感性,同时对解释时间的影响最小,并支持将这种实现应用于日常临床实践中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号