The objective of this study was to identify the critical temperature, at or below which heat-treatment of bovine colostrum would produce no significant changes in viscosity, IgG concentration, or Ig activity. Results of preliminary work, using a Rapid Visco Analyzer (RVA) to heat 50-mL aliquots from 6 unique batches of bovine colostrum at 59, 60, 61, 62, and 63℃, suggested that colostrum could be heated to 60℃ for up to 120 min without changing viscosity or IgG concentration. This finding was confirmed by heating 50-mL aliquots from 30 unique batches of colostrum in an RVA for 120 min at 60 and 63℃. Heating colostrum to 63℃ resulted in an estimated 34% decrease in IgG concentration and 33% increase in viscosity. However, there was no difference in IgG concentration between pre-heat-treated (73.4 ± 26.5 mg/mL) and post-heat-treated (74.5 ± 24.3 mg/mL) samples after heating colostrum to 60℃ in an RVA for 120 min. Similarly, viscosity was unaffected after heating colostrum to 60℃ in an RVA for 120 min. High quality colostrum ( ≥ 73.0 mg/mL) suffered greater losses of IgG and greater viscosity changes when heated to 63℃ than did moderate quality colostrum ( < 73.0 mg/mL). However, the effects of colostrum quality were minor if high quality colostrum was only heated to 60℃. The results of a bovine viral diarrhea serum neutralization assay suggested that antibody activity was unchanged after heating colostrum to either 60 or 63℃. However, these results were interpreted as being inconclusive due to a high proportion of missing results because of the congealing of many samples after heat treatment. The results of this study indicate that 50-mL volumes of bovine colostrum can be heat treated at 60℃ for up to 120 min in an RVA without affecting IgG concentration or viscosity.
机译:这项研究的目的是确定临界温度,在该温度以下,牛初乳的热处理不会使粘度,IgG浓度或Ig活性产生明显变化。初步工作的结果是,使用快速粘度分析仪(RVA)在59、60、61、62和63℃下加热6个独特批次的牛初乳中的50 mL等分试样,表明初乳可以加热到60℃以上。至120分钟,而不会改变粘度或IgG浓度。通过在60和63℃的RVA中加热30个独特批次的初乳中的50 mL等分试样120分钟来证实这一发现。将初乳加热至63℃可使IgG浓度降低34%,粘度增加33%。然而,在RVA中将初乳加热至60℃120分钟后,预热处理(73.4±26.5 mg / mL)和热处理后(74.5±24.3 mg / mL)样品之间的IgG浓度没有差异。 。同样,在RVA中将初乳加热至60℃120分钟后,粘度也不受影响。与中等质量的初乳(<73.0 mg / mL)相比,加热至63℃时,高质量的初乳(≥73.0 mg / mL)遭受更大的IgG损失和更大的粘度变化。但是,如果仅将优质初乳加热到60℃,初乳质量的影响就很小。牛病毒性腹泻血清中和试验的结果表明,将初乳加热到60或63℃后,抗体活性没有变化。然而,由于许多结果在热处理后会凝结,因此这些结果被认为是不确定的,因为有很大一部分结果缺失。这项研究的结果表明,可以在RVA中于60℃将50mL牛初乳热处理长达120分钟,而不会影响IgG的浓度或粘度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号