...
首页> 外文期刊>Journal of dairy science >Short communication: Validation of a point-of-care glucometer for use in dairy cows
【24h】

Short communication: Validation of a point-of-care glucometer for use in dairy cows

机译:简短交流:用于奶牛的即时血糖仪的验证

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study was to evaluate the diagnostic performance of a hand-held electronic glucometer (Precision Xtra; Abbott Diabetes Care Inc., Mississauga, ON, Canada) for cow-side use in dairy cattle. This device has been validated for measuring blood concentrations of β-hydroxybutyrate in dairy cows. This study was designed to assess the accuracy of whole-blood glucose measurements from the glucose meter relative to a reference chemical analyzer in a diagnostic laboratory. Duplicate samples were taken from the same cows at the same time, into blood tubes with either the glycolysis-inhibiting preservative sodium fluoride (NaF) or without preservative. Glucometer readings were taken on whole blood with no preservative, and laboratory measurements were conducted on serum preserved with NaF. Blood samples were collected from cows between 3 wk before and 5 wk after calving, including during a glucose tolerance test conducted 1 wk before expected calving. Passing-Bablok and Bland-Altman data analyses were used to evaluate the performance of the glucometer relative to the laboratory results. A strong correlation was observed in 709 samples from 81 cows between the hand-held meter and serum from samples preserved with NaF (R2 = 0.95). Overall, 96% of measurements with the glucometer fell within the 95% confidence limits of analysis in the laboratory, although at higher-than-physiologic glucose concentrations (>5.2 mmol/L) the glucometer tended to overestimate. The hand-held glucometer appears suitable for rapid measurement of glucose under field conditions in dairy cattle.
机译:这项研究的目的是评估手持式电子血糖仪(Precision Xtra;加拿大安大略省密西沙加的雅培糖尿病护理公司)在奶牛侧使用的诊断性能。该设备已经过验证,可以测量奶牛的β-羟基丁酸血药浓度。本研究旨在评估血糖仪相对于诊断实验室中参考化学分析仪的全血葡萄糖测量的准确性。在同一时间从同一头奶牛中采集双份样品,将其放入带有抑制糖酵解的防腐剂氟化钠(NaF)或不含防腐剂的血管中。血糖仪读数是在没有防腐剂的情况下对全血采集的,实验室测量是对用NaF保存的血清进行的。在产犊前3周到产后5周之间,包括在预期产犊前1周进行的葡萄糖耐量试验期间,从母牛身上采集血样。 Passing-Bablok和Bland-Altman数据分析用于评估血糖仪相对于实验室结果的性能。在手持式仪表和NaF保存的血清中,在81头奶牛的709个样品中观察到了很强的相关性(R2 = 0.95)。总体而言,尽管在高于生理葡萄糖浓度(> 5.2 mmol / L)的情况下,血糖仪往往被高估,但96%的血糖仪测量值仍在实验室分析的95%置信度范围内。手持式血糖仪似乎适合在野外条件下快速测量奶牛中的葡萄糖。

著录项

  • 来源
    《Journal of dairy science》 |2013年第7期|4514-4518|共5页
  • 作者单位

    Department of Population Medicine, Ontario Veterinary College, University of Guelph, Guelph, Ontario, N1G 2W1, Canada;

    Department of Population Medicine, Ontario Veterinary College, University of Guelph, Guelph, Ontario, N1G 2W1, Canada;

    Department of Population Medicine, Ontario Veterinary College, University of Guelph, Guelph, Ontario, N1G 2W1, Canada;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    glucometer; insulin resistance; glucose tolerance test; peripartum;

    机译:血糖仪胰岛素抵抗;葡萄糖耐量试验;围产期;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号