Finite element method is applied for the calculations of temperature fields of concrete filled steel tubes under fire. A theoretical model that calculates deformations and strength of beam- column in fire and fire resistance is described in this paper. A comparison of results calculated using this model with the results of tests shows good agreement. Based on the theoretical model, the influence of the changing strength of the materials, sectional dimensions, steel ratio, load eccentricity and slenderness ratio on the fire resistance are discussed.
机译:采用有限元法计算了火灾下钢管混凝土的温度场。本文描述了一种计算梁柱在火中的变形和强度以及耐火性的理论模型。使用此模型计算出的结果与测试结果的比较显示出很好的一致性。在理论模型的基础上,讨论了材料的变化强度,截面尺寸,钢比,载荷偏心率和细长比对耐火性的影响。