The present paper aims to experimentally investigate the behaviour of rectangular concrete-filled steel tubular (RCFST) stub columns loaded axially on a partially stressed cross-sectional area. A total of twenty-two specimens, including thirteen partially loaded composite specimens, six partially loaded plain concrete reference specimens and three corresponding fully loaded composite specimens, were tested under concentric loads. The main parameters varied in the tests are: (1) depth-to-width ratio of the rectangular sections: from 1.2 to 1.8; (2) partial compression area ratio (concrete cross-sectional area to partial compression area): from 1.44 to 17.42; (3) steel wall thickness of top endplate: from 0 mm to 12 mm; and (4) shape of the bearing plate for partial compression: rectangular and strip. The test results showed that, while being loaded on partial cross-sectional area, RCFST stub column had a favourable bearing capacity and ductility compared with the corresponding plain concrete specimens. Simplified formulae were used for the prediction of the ultimate strength of CFST stub columns loaded on partial cross-sectional area.
机译:本文旨在通过实验研究在部分受压截面上轴向加载的矩形钢管混凝土(RCFST)短柱的性能。在同心载荷下共测试了22个试样,包括13个部分荷载的复合试样,6个部分荷载的普通混凝土参考试样和3个相应的完全荷载的复合试样。测试中变化的主要参数是:(1)矩形截面的长宽比:从1.2到1.8; (2)局部压缩面积比(混凝土截面积与局部压缩面积之比):1.44〜17.42; (3)顶板的钢板壁厚:0mm至12mm; (4)局部压缩的承压板的形状:矩形和带状。试验结果表明,RCFST短柱在承受部分横截面载荷时,与相应的普通混凝土试样相比,具有良好的承载力和延性。简化的公式用于预测加载到部分横截面上的CFST短柱的极限强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号