首页> 外文期刊>Journal of Constructional Steel Research >Hybrid steel plate girders subjected to patch loading, Part 2: Design proposal
【24h】

Hybrid steel plate girders subjected to patch loading, Part 2: Design proposal

机译:承受补片荷载的混合钢板梁,第2部分:设计建议

获取原文
获取原文并翻译 | 示例
       

摘要

The resistance of plate girders subjected to patch loading has been studied thoroughly for the case of homogenous girders. The particular case of hybrid girders has been generally treated identically than for homogenous specimens. In this paper, the current EN1993-1-5 formulation is evaluated and some peculiarities concerning the treatment of hybrid girders subjected to patch loading are pinpointed. It is numerically demonstrated that the moment capacity of the flanges does not play any role in the resistance of plate girders to patch loading as predicted in EN1993-1-5. Accordingly, a design proposal which corrects the current EN1993-1-5 formulation is presented at the end of the paper.
机译:对于均质梁的情况,已经充分研究了承受贴片荷载的板梁的抗力。混合梁的特殊情况通常与均质样品相同。在本文中,对当前的EN1993-1-5配方进行了评估,并指出了有关处理贴片荷载的混合大梁的一些特殊性。数值证明,如EN1993-1-5中所预测的那样,法兰的弯矩承载力在板梁对拼块荷载的抵抗中没有任何作用。因此,在本文的最后提出了纠正当前EN1993-1-5公式的设计建议。

著录项

  • 来源
    《Journal of Constructional Steel Research》 |2010年第5期|709-715|共7页
  • 作者

    R. Chacon; E. Mirambell; E. Real;

  • 作者单位

    Construction Engineering Department, Universitat Politecnica de Catalunya, Barcelona, Spain;

    Construction Engineering Department, Universitat Politecnica de Catalunya, Barcelona, Spain;

    Construction Engineering Department, Universitat Politecnica de Catalunya, Barcelona, Spain;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    patch loading; hybrid girders;

    机译:补丁加载;混合梁;
  • 入库时间 2022-08-18 00:16:10