Due to the ease of fabrication and construction, gusset plate connections with single-sided splice members are a popular connection type in building frames and light structures. However, this detail produces local out-of-plane eccentricity, which can be detrimental to the ultimate strength of the connections. This paper presents experimental, numerical, and analytical investigations of the compressive behaviour of eccentrically loaded gusset plate connections. Three full-scale tests were conducted, including two specimens with unstiffened splice members and the remaining one with stiffened splice members. The ultimate loads of the three specimens were found to be evidently less than the concentrically loaded specimen which has been earlier reported. Finite element (FE) models were then established, which were validated through comparisons against the test results. The sensitivity of the FE models to the initial imperfections was also studied. An extensive parametric study was subsequently performed, and the influences of varying gusset plate and splice member geometric configurations were discussed in detail. Three key failure modes were identified for the eccentrically loaded gusset plate connections, namely, Gusset-Splice Interactive Plastic Failure (G-SIPF), Splice Plastic Failure (SPF), and Gusset Plate Buckling (GPB). A et of design rules based on the nature of each failure mode was proposed accordingly, where good agreements were observed between the FE and the design results in terms of both the ultimate load and the governing failure mode. Worked examples were finally provided to clearly illustrate the proposed design procedure. (C) 2014 Elsevier Ltd. All rights reserved.
机译:由于易于制造和构造,在建筑框架和轻型结构中,具有单面拼接构件的角撑板连接是一种流行的连接类型。但是,此细节会导致局部平面外偏心,这可能会不利于连接的最终强度。本文介绍了偏心加载的角撑板连接的压缩行为的实验,数值和分析研究。进行了三项全面测试,包括两个带有未加固接头构件的标本,另一个是带有加固接头构件的标本。发现三个样品的极限载荷明显小于早先报道的同心载荷样品。然后建立有限元(FE)模型,并通过与测试结果进行比较进行验证。还研究了有限元模型对初始缺陷的敏感性。随后进行了广泛的参数研究,并详细讨论了不同的角撑板和接头构件几何构型的影响。对于偏心加载的角撑板板连接,确定了三种关键的失效模式,分别是角撑板-拼接交互式塑性破坏(G-SIPF),拼接塑性破坏(SPF)和角撑板屈曲(GPB)。相应地提出了一种基于每种失效模式的性质的设计规则,其中在极限载荷和控制失效模式方面都观察到了有限元与设计结果之间的良好一致性。最后提供了工作示例,以清楚地说明建议的设计程序。 (C)2014 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号