首页> 外文期刊>Journal of Constructional Steel Research >Bond behavior in concrete-filled steel tubes
【24h】

Bond behavior in concrete-filled steel tubes

机译:钢管混凝土中的粘结行为

获取原文
获取原文并翻译 | 示例
       

摘要

In this paper, the bond behavior between the steel tube and the concrete in concrete-filled steel tubes (CFST) is investigated. A series of push-out tests on circular and square CFST specimens were conducted, and the main parameters considered in the test program were: (a) cross-sectional dimension (120-600 mm); (b) steel type (carbon and stainless steels); (c) concrete type (normal, recycled aggregate and expansive concretes); (d) concrete age (31-1176 days); and (e) interface type (normal interface, interface with shear studs and interface with an internal ring). The experimental results indicate that stainless steel CFST columns have lower bond strength compared with carbon steel counterparts, and the bond strength decreases remarkably with increasing cross-sectional dimension and concrete age. To enhance the bond strength, welding internal ring(s) onto the inner surface of the steel tube is the most effective method, followed by the methods of welding shear studs and using expansive concrete. (C) 2016 Elsevier Ltd. All rights reserved.
机译:本文研究了钢管混凝土中钢管与混凝土之间的粘结性能。在圆形和方形CFST样品上进行了一系列推出试验,测试程序中考虑的主要参数为:(a)横截面尺寸(120-600 mm); (b)钢种(碳钢和不锈钢); (c)混凝土类型(普通,再生骨料和膨胀混凝土); (d)具体年龄(31-1176天); (e)界面类型(普通界面,带剪切螺柱的界面和带内环的界面)。实验结果表明,与碳钢同类产品相比,不锈钢CFST柱的粘结强度更低,并且随着截面尺寸和混凝土龄期的增加,粘结强度显着降低。为了提高粘结强度,将内圈焊接到钢管的内表面是最有效的方法,其次是焊接抗剪螺柱和使用膨胀混凝土的方法。 (C)2016 Elsevier Ltd.保留所有权利。