首页> 外文期刊>Journal of Constructional Steel Research >Simplified direct loss measure for seismic isolated steel moment-resisting structures
【24h】

Simplified direct loss measure for seismic isolated steel moment-resisting structures

机译:隔震钢制抗弯结构的简化直接损失测度

获取原文
获取原文并翻译 | 示例
       

摘要

Seismic base isolation provides an effective means for resilient structures, protects structures from the damaging effect of seismic action and reduces structural vibration, casualties and financial losses. The life cycle costs and advantages of using base isolation can be quantitatively supported by using the FEMA P-58 methodology, but damage and loss estimation using such an approach is time consuming and costly. This study presents a new direct loss measure (LM) for seismic isolated steel moment-resisting structures. Three steel moment-resisting frames of 4, 6 and 8 stories were studied with and without isolation system and 3D nonlinear model of the structures was developed in Opensees. Using common incremental dynamic analysis (IDA) under far-field and near-field records, the expected annual loss (EAL) based on FEMA P-58 approach was estimated. In this regard, LM was introduced for rapid modeling of response based on two main sources of structural damage, that is, interstory drift ratio and peak floor acceleration considering structural and non-structural elements. A good correlation was observed between the EAL and proposed LM. The fixed-base structures were subject to extensive damage and complete failure in the maximum considered earthquakes (MCE), while the base-isolated structures were subject to moderate failure rate in the same situation, indicating the resilience of these structures. The proposed LM can be used for prompt and efficient loss estimation of the base-isolated structures and demonstrate the cost-effective seismic risk management of these systems. (C) 2018 Elsevier Ltd. All rights reserved.
机译:地震基础隔离为弹性结构提供了一种有效的手段,可以保护结构免受地震作用的破坏,并减少结构的振动,人员伤亡和财务损失。通过使用FEMA P-58方法可以定量支持使用生命周期成本和使用基本隔离的优势,但是使用这种方法进行损坏和损失估算是耗时且昂贵的。这项研究提出了一种新的针对地震隔离的钢制抗弯结构的直接损失量度(LM)。研究了带有和不带有隔离系统的三个4、6和8层钢制抗弯框架,并在Opensees中开发了结构的3D非线性模型。使用远场和近场记录下的通用增量动态分析(IDA),根据FEMA P-58方法估算了预期的年度损失(EAL)。在这方面,引入LM来基于结构损坏的两个主要来源对响应进行快速建模,即考虑结构和非结构元素的层间漂移率和峰底加速度。在EAL和提议的LM之间观察到良好的相关性。固定基础结构在最大考虑地震(MCE)中遭受了广泛的破坏和完全破坏,而基础隔离结构在相同情况下遭受了中等破坏率,表明了这些结构的弹性。所提出的LM可用于对基础隔震结构进行迅速而有效的损失估算,并证明这些系统具有成本效益的地震风险管理。 (C)2018 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号