首页> 外文期刊>Journal of Constructional Steel Research >Compression loading test for concrete-filled tubular columns with high-strength steel slender section
【24h】

Compression loading test for concrete-filled tubular columns with high-strength steel slender section

机译:高强度钢细长型钢管混凝土柱的压缩荷载试验

获取原文
获取原文并翻译 | 示例

摘要

An experimental study was performed on thin-walled concrete-filled steel tubular (CFT) columns. In practical applications of CFT columns, the use of high-strength steel non-compact or slender section is expected to grow because thin plates are advantageous in steel production and economy. Thus, the present study focused on evaluation of the axial load-carrying capacity of rectangular CFT columns with high-strength steel (grade 800) slender section. The test parameters were the yield strength of steel, the width-to-thickness ratio of steel plates, and the use of stiffeners. Five specimens were tested under monotonic axial-compression loading. Although elastic local buckling occurred in the high-strength steel slender sections, unlike the expectation, the specimens exhibited significant post-buckling reserve strength, exceeding design code predictions. The specimens strengthened with vertical stiffeners showed enhanced performance, attaining the plastic capacity of the composite section. To investigate the characteristic behaviors such as steel local bucking and concrete confinement, nonlinear finite element analysis was performed on the specimens. The experimental and numerical results showed that the steel peak stress is affected by the lateral expansion of the crushed concrete, and the peak stress of the high-strength concrete is generally lower than the cylinder strength. On the basis of the results, a modified fiber analysis model and a simplified strength equation were proposed. (C) 2019 Elsevier Ltd. All rights reserved.
机译:在薄壁钢管混凝土(CFT)柱上进行了实验研究。在CFT柱的实际应用中,由于薄板有利于钢的生产和经济性,预计将增加使用高强度钢的非紧凑或细长截面。因此,本研究着重于评估具有高强度钢(800级)细长截面的矩形CFT柱的轴向承载能力。测试参数为钢板的屈服强度,钢板的宽厚比以及加劲肋的使用。在单调轴向压缩载荷下测试了五个样本。尽管在高强度钢细长截面中发生了弹性局部屈曲,但与预期不同的是,样品表现出了显着的屈曲后保留强度,超出了设计规范的预测。用垂直加强筋加强的试样表现出增强的性能,达到了复合截面的塑性能力。为了研究诸如钢局部屈曲和混凝土约束等特征行为,对样本进行了非线性有限元分析。实验和数值结果表明,钢的峰值应力受压碎混凝土的侧向膨胀的影响,而高强度混凝土的峰值应力通常低于圆柱强度。在此基础上,提出了改进的纤维分析模型和简化的强度方程。 (C)2019 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号