首页> 外文期刊>Journal of Composites for Construction >Postrepair Fatigue Performance of FRP-Repaired Corroded RC Beams: Experimental and Analytical Investigation
【24h】

Postrepair Fatigue Performance of FRP-Repaired Corroded RC Beams: Experimental and Analytical Investigation

机译:FRP修复的锈蚀RC梁的修复后疲劳性能:实验和分析研究

获取原文
获取原文并翻译 | 示例
           

摘要

This paper presents the results of an experimental and analytical study of the fatigue performance of corroded reinforced concrete (RC) beams repaired with fiber-reinforced polymer (FRP) sheets. Ten RC beam specimens (152 x 254 x 3,200 mm) were constructed. One specimen was neither strengthened nor corroded to serve as a reference; three specimens were corroded and not repaired; another three specimens were corroded and repaired with U-shaped glass FRP sheets that wrapped the cross section of the specimen; and the remaining three specimens were corroded and repaired with U-shaped glass FRP sheets for wrapping and carbon-fiber-reinforced polymer (CFRP) sheets for flexural strengthening. The FRP sheets were applied after the main reinforcing bars were corroded to an average mass loss of 5.5%. Following FRP repair, some specimens were tested immediately to failure, while the other repaired specimens were subjected to further corrosion before being tested to failure to investigate their postrepair (long-term) performance. Reinforcement steel pitting due to corrosion reduced the fatigue life significantly. The FRP wrapping had no significant effect on the fatigue performance, while using CFRP sheets for flexural strengthening enhanced the fatigue performance significantly. The fatigue results were compared to smooth specimen fatigue data to estimate an equivalent fatigue notch factor for the main reinforcing bars of the tested specimens.
机译:本文介绍了用纤维增强聚合物(FRP)板修复的锈蚀钢筋混凝土(RC)梁的疲劳性能的实验和分析研究结果。制作了十个RC梁标本(152 x 254 x 3,200 mm)。一个标本既没有加强也没有被腐蚀,可以作为参考。三个标本被腐蚀且未修复;另外三个样品被腐蚀并用包裹样品横截面的U形玻璃钢片进行修复。其余三个样品被腐蚀并用U型玻璃纤维增​​强塑料板包裹和碳纤维增强聚合物(CFRP)弯曲修复。在主要钢筋受腐蚀至平均质量损失为5.5%之后,再施加FRP板。 FRP修复后,立即对一些标本进行了破坏测试,而其他修复后的标本则经过进一步腐蚀,然后再进行测试以研究其维修后(长期)性能。腐蚀引起的钢筋点蚀显着降低了疲劳寿命。 FRP包裹对疲劳性能没有显着影响,而使用CFRP片材进行抗弯加固可显着提高疲劳性能。将疲劳结果与光滑试样的疲劳数据进行比较,以估计测试试样的主要钢筋的等效疲劳缺口系数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号