Behavior of Aramid Fiber-Reinforced Polymer Reinforced High Strength Concrete Beams under Bending

机译:芳纶纤维增强聚合物高强混凝土梁受弯性能

获取原文
获取原文并翻译 | 示例

摘要

Flexural test results of ten high strength concrete beams reinforced with aramid fiber-reinforced polymer (AFRP) bars together with a steel-reinforced beam that served as a reference are presented and discussed. All beams were tested under third-point loading. Test results have shown that a concrete beam, when reinforced with AFRP bars, becomes more flexible in the postcracking range than an equivalent steel-reinforced beam, demonstrates wider and predominantly vertical cracks even in the shear span, and may fail in an unusual flexure-shear mode. Major critical issues concerning flexural designs of AFRP-reinforced beams have been discussed in the perspective of code provisions, and suitable recommendations are made for practical design. A method has been suggested to provide a meaningful quantification of ductility for FRP-reinforced beams. Also the need for reducing the maximum spacing of stirrups from that specified in the current code provisions for sections subjected to large shear combined with significant bending moment has been identified and recommendations are made.
机译:介绍并讨论了用芳纶纤维增强聚合物(AFRP)棒增强的十根高强度混凝土梁以及作为参考的钢增强梁的抗弯试验结果。所有梁都在第三点载荷下进行了测试。测试结果表明,用AFRP筋加固的混凝土梁,在开裂后的范围内比同等的钢筋加固的梁更加柔韧性,即使在剪切跨度下,也显示出更宽且主要是垂直的裂缝,并且可能会因异常弯曲而失效。剪切模式。从规范的角度讨论了有关AFRP加固梁抗弯设计的主要关键问题,并为实际设计提出了适当的建议。已经提出了一种方法,可以为FRP增强梁提供有意义的延性量化。另外,已经确定有必要从现行规范中规定的箍筋的最大间距减小最大剪切力和较大弯矩的截面的最大箍筋间距,并提出了建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号