首页> 外文期刊>Journal of Clinical Pathology >High temperature antigen retrieval and loss of nuclear morphology: a comparison of microwave and autoclave techniques.
【24h】

High temperature antigen retrieval and loss of nuclear morphology: a comparison of microwave and autoclave techniques.

机译:高温抗原回收和核形态损失:微波技术和高压灭菌技术的比较。

获取原文
获取原文并翻译 | 示例
       

摘要

The use of high temperature antigen retrieval methods has been of major importance in increasing the diagnostic utility of immunocytochemistry. However, these techniques are not without their problems and in this report attention is drawn to a loss of nuclear morphological detail, including mitotic figures, following microwave antigen retrieval. This was not seen with an equivalent autoclave technique. This phenomenon was quantified using image analysis in a group of B cell lymphomas stained with the antibody L26. Loss of nuclear morphological detail may lead to difficulty in identifying cells accurately, which is important in the diagnostic setting-for example, when trying to distinguish a malignant lymphoid infiltrate within a mixed cell population. In such cases it would clearly be wise to consider the use of alternative high temperature retrieval methods and accept their slightly lower staining enhancement capability compared with the microwave technique.
机译:在提高免疫细胞化学的诊断效用中,高温抗原回收方法的使用已具有重要意义。但是,这些技术并非没有问题,在本报告中,人们将注意力转移到了微波抗原回收后核形态细节的丢失,包括有丝分裂图。用等效的高压釜技术看不到这一点。使用图像分析对一组被抗体L26染色的B细胞淋巴瘤进行了定量分析。核形态学细节的丢失可能导致难以准确识别细胞,这在诊断环境中非常重要-例如,当试图区分混合细胞群中的恶性淋巴浸润时。在这种情况下,考虑使用替代的高温回收方法并接受与微波技术相比稍低的染色增强能力显然是明智的。