首页> 外文期刊>Journal of Applied Physics >Non-destructive testing of composite plates by holographic vibrometry
【24h】

Non-destructive testing of composite plates by holographic vibrometry

机译:全息振动法对复合板进行无损检测

获取原文
获取原文并翻译 | 示例

摘要

We report on a wide-field optical monitoring method for revealing local delaminations in sandwich-type composite plates at video-rate by holographic vibrometry. Non-contact measurements of low frequency flexural waves is performed with time-averaged heterodyne holography. It enables narrowband imaging of local out-of-plane nanometric vibration amplitudes under sinusoidal excitation and reveals delamination defects, which cause local resonances of flexural waves. The size of the defect can be estimated from the first resonance frequency of the flexural wave and the mechanical parameters of the observed layer of the composite plate.
机译:我们报告了一种通过全息振动法揭示视频速率下的三明治型复合板中局部分层的广域光学监测方法。低频弯曲波的非接触式测量是通过时间平均外差全息术进行的。它能够在正弦激励下对局部平面外纳米振动幅度进行窄带成像,并揭示分层缺陷,这些缺陷会引起弯曲波的局部共振。缺陷的大小可以从弯曲波的第一共振频率和复合板的观察层的机械参数来估计。

著录项

  • 来源
    《Journal of Applied Physics 》 |2014年第15期| 154503.1-154503.4| 共4页
  • 作者单位

    Institut Langevin, Fondation Pierre-Gilles de Gennes, Centre National de la Recherche Scientifique (CNRS) UMR 7587, Institut National de la Sante et de la Recherche Medicale (INSERM) U 979, Universite Pierre et Marie Curie (UPMC), Universite Paris 7, Ecole Superieure de Physique et de Chimie Industrielles (ESPCI ParisTech)-1 rue Jussieu, 75005 Paris, France;

    Institut Langevin, Fondation Pierre-Gilles de Gennes, Centre National de la Recherche Scientifique (CNRS) UMR 7587, Institut National de la Sante et de la Recherche Medicale (INSERM) U 979, Universite Pierre et Marie Curie (UPMC), Universite Paris 7, Ecole Superieure de Physique et de Chimie Industrielles (ESPCI ParisTech)-1 rue Jussieu, 75005 Paris, France;

    Institut Langevin, Fondation Pierre-Gilles de Gennes, Centre National de la Recherche Scientifique (CNRS) UMR 7587, Institut National de la Sante et de la Recherche Medicale (INSERM) U 979, Universite Pierre et Marie Curie (UPMC), Universite Paris 7, Ecole Superieure de Physique et de Chimie Industrielles (ESPCI ParisTech)-1 rue Jussieu, 75005 Paris, France;

    Composite Structures and Materials Department, Office National d'Etudes et de Recherches Aeronautiques (ONERA), BP72-29 avenue de la Division Leclerc, 92322 Chatillon Cedex, France;

    Composite Structures and Materials Department, Office National d'Etudes et de Recherches Aeronautiques (ONERA), BP72-29 avenue de la Division Leclerc, 92322 Chatillon Cedex, France;

    Institut Langevin, Fondation Pierre-Gilles de Gennes, Centre National de la Recherche Scientifique (CNRS) UMR 7587, Institut National de la Sante et de la Recherche Medicale (INSERM) U 979, Universite Pierre et Marie Curie (UPMC), Universite Paris 7, Ecole Superieure de Physique et de Chimie Industrielles (ESPCI ParisTech)-1 rue Jussieu, 75005 Paris, France;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号