A simple cold vapour generator is described that addresses problems with sample foaming, signal drift and memory effects associated with the wetting of gas-liquid separator membranes. The device is operated in continuous flow mode attached to an atomic absorption spectrometer. Method validation was carried out using BCR 186 Porcine Kidney reference material, with recovery averaging 97% with an estimated 3 s detection limit of 0.38 ppb Hg.
机译:描述了一种简单的冷蒸汽发生器,该发生器解决了与气液分离器膜润湿相关的样品起泡,信号漂移和记忆效应的问题。该设备以连接于原子吸收光谱仪的连续流动模式运行。使用BCR 186猪肾参考物质进行方法验证,回收率平均为97%,估计3 s的检出限为0.38 ppb Hg。