...
首页> 外文期刊>Journal of the air & waste management association >Temperature dependence of nickel stabilization in inorganic oxide matrices
【24h】

Temperature dependence of nickel stabilization in inorganic oxide matrices

机译:无机氧化物基质中镍稳定化的温度依赖性

获取原文
获取原文并翻译 | 示例

摘要

Scanning electron microscopy, X-ray diffractometry, X-ray absorption spectroscopy, and other means are used to investigate the effect of thermal treatment temperature, 105-1100 degrees C, on the immobilization of nickel (Ni) by the inorganic oxides of latosol. Ni is more firmly immobilized by the latosol with increasing temperature. Spectral analyses indicate that a shoulder toward the edge-jump appears in the spectra of X-ray absorption near-edge structure for the samples heated at 900 and 1100 degrees C. Moreover, the intensity, of the main peak at the edge increases with higher temperature; this information indicates the distortion of the divalent nickel [Ni(II)] environment in the samples heated at 900 and 1100 degrees C. Nevertheless, the distortion is absent from the samples heated at 105 and 500 degrees C. The fact of the distortion of the Ni(II) environment suggests the occurrence of a chemical reaction between the Ni compound and the inorganic matrices of,the latosol soil during the heating process at 900 and 1100 degrees C. In addition, the extended X-ray absorption fine structure results correspond well to the X-ray absorption near-edge structure results; the former are supportive of the occurrence of a distorted Ni(II) environment in the samples heated at 900 and 1100 degrees C. The wet-chemistry results, show that the samples heated-at 900-1100 degrees C leach less Ni than the 105-500 degrees C samples do. The change of the Ni environment is related to the observation that less Ni is leached from the samples heated at 900-1100 degrees C. Furthermore, the pore closing phenomenon is observed only in the 1100 degrees C sample this phenomenon corresponds with the fact that the 1100 degrees C sample leaches less Ni than the 900 degrees C sample does.
机译:扫描电子显微镜,X射线衍射仪,X射线吸收光谱仪和其他手段用于研究热处理温度105-1100摄氏度对latosol无机氧化物固定化镍(Ni)的影响。随着温度的升高,镍被Latosol更牢固地固定。光谱分析表明,在900和1100摄氏度下加热的样品的X射线吸收近边缘结构的光谱中出现了一个指向边缘跳跃的肩部。此外,边缘处的主峰的强度随着温度的升高而增加。温度;此信息表明在900和1100摄氏度下加热的样品中二价镍[Ni(II)]环境的变形。尽管如此,在105和500摄氏度下加热的样品中不存在这种变形。 Ni(II)环境表明在900和1100摄氏度的加热过程中,镍化合物与Latosol土壤的无机基质之间发生了化学反应。此外,扩展的X射线吸收精细结构结果对应很好地吸收了X射线的近边缘结构结果;前者支持在900和1100摄氏度下加热的样品中扭曲的Ni(II)环境的发生。湿化学结果表明,在900-1100摄氏度下加热的样品中的镍比105少-500摄氏度的样品呢。 Ni环境的变化与以下事实有关:从900-1100摄氏度加热的样品中沥出的镍较少。此外,仅在1100摄氏度样品中观察到了闭孔现象,这一现象与以下事实相对应: 1100摄氏度的样品比900摄氏度的样品浸出的镍更少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号