In this study, long-term aerosol particle total number concentration measurements in five metropolitan areas across Europe are presented. The measurements have been carried out in Augsburg, Barcelona, Helsinki, Rome, and Stockholm using the same instrument, a condensation particle counter (TSI model 3022). The results show that in all of the studied cities, the winter concentrations are higher than the summer concentrations. In Helsinki and in Stockholm, winter concentrations are higher by a factor of two and in Augsburg almost by a factor of three compared with summer months. The winter maximum of the monthly average concentrations in these cities is between 10,000 cm~(-3) and 20,000 cm~(-3), whereas the summer min is ~5000-6000 cm~(-3). In Rome and in Barcelona, the winters are more polluted compared with summers by as much as a factor of 4-10. The winter maximum in both Rome and Barcelona is close to 100,000 cm~(-3), whereas the summer minimum is > 10,000 cm~(-3.) During the weekdays the maximum of the hourly average concentrations in all of the cities is detected during the morning hours between 7 and 10 a.m. The evening maxima were present in Barcelona, Rome, and Augsburg, but these were not as pronounced as the morning ones. The daily maxima in Helsinki and Stockholm are close or even lower than the daily minima in the more polluted cities. The concentrations between these two groups of cities are different with a factor of about five during the whole day. The study pointed out the influence of the selection of the measurement site and the configuration of the sampling line on the observed concentrations.
机译:在这项研究中,介绍了欧洲五个大都市地区的长期气溶胶颗粒总数浓度测量结果。测量是在奥格斯堡,巴塞罗那,赫尔辛基,罗马和斯德哥尔摩使用相同的仪器,即凝结粒子计数器(TSI 3022型)进行的。结果表明,在所有研究城市中,冬季的浓度都高于夏季的浓度。与夏季月份相比,赫尔辛基和斯德哥尔摩的冬季浓度高出两倍,奥格斯堡的冬季浓度高出近三倍。这些城市的冬季平均月最高浓度在10,000 cm〜(-3)至20,000 cm〜(-3)之间,而夏季最低值在〜5000-6000 cm〜(-3)之间。在罗马和巴塞罗那,与夏天相比,冬天的污染更为严重,高达4-10倍。罗马和巴塞罗那的冬季最大值接近100,000 cm〜(-3),而夏季最小值则大于10,000 cm〜(-3)。在工作日中,所有城市的小时平均浓度最大值都被检测到在上午7点至10点之间的早晨时段,巴塞罗那,罗马和奥格斯堡的夜晚达到最大值,但不如早晨的明显。赫尔辛基和斯德哥尔摩的每日最大值接近甚至低于污染较严重城市的每日最小值。这两类城市之间的集中度在一天当中大约是五分之一。研究指出了测量位置的选择和采样管线的配置对所观察到的浓度的影响。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号