Five different models of dosimeters were compared in the Chernobyl Inner Exclusion Zone by measuring gamma radiation in 12 locations. We used an instrument made by Mirion Technologies, Inc., as the reference, since that instrument had an NIST-traceable calibration. Two models of dosimeters gave radiation values similar to the Mirion at all levels of radiation encountered. Two other models gave similar values to the Mirion instrument at low radiation levels but not at higher radiation levels encountered. These results offer a caution regarding the accuracy of inexpensive commercially available radiation instruments. Implications: Comparison of gamma ray dosimeters in the Chernobyl Exclusion Zone showed varying agreement with an NIST-calibrated instrument, as well as varying linearity of response to ambient radiation. These results suggest caution regarding accuracy of inexpensive dosimeters. However, dosimeters used that were manufactured in Ukraine exhibited good agreement with the reference instrument.
机译:通过在12个位置测量伽马射线,在切尔诺贝利内部禁区比较了五种不同的剂量计模型。我们使用Mirion Technologies,Inc.制造的仪器作为参考,因为该仪器具有NIST可追溯的校准。在遇到的所有辐射水平下,两种剂量计模型给出的辐射值均类似于Mirion。另外两个模型在低辐射水平下与Mirion仪器具有相似的值,但在遇到较高辐射水平时却没有。这些结果为廉价的市售辐射仪器的准确性提供了警告。启示:切尔诺贝利禁区中的伽马射线剂量计的比较显示,其与NIST校准仪器的一致性不同,并且对环境辐射的响应线性也不同。这些结果表明对廉价剂量计的准确性要谨慎。但是,在乌克兰制造的剂量计与参考仪器显示出良好的一致性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号