In this paper, by defining and solving an optimization problem, amount of distributed generators (DGs) and reactive power sources (RSs) in selected buses of a distribution system are computed to make up a given total of distributed generation for minimizing losses, line loadings, and total required reactive power capacity. The formulated problem is a combinatorial problem, therefore Tabu search algorithm is applied for solving the optimization problem. Results of solving the optimization problem for a radial 33-bus distribution system and a meshed 6-bus system are presented. When using less amount of reactive capacity, regarding tap positions of voltage regulators as control variables has considerable role in loss reduction and improvement of voltage profile. In the case of meshed systems, including line loadings in the cost function can significantly change results of solving the optimization problem such as amount of the required reactive capacity and how to assign DGs and RSs to the selected buses.
机译:在本文中,通过定义和解决优化问题,可以计算配电系统中选定母线中的分布式发电机(DG)和无功功率(RS)的数量,以组成给定的总分布式发电量,以最大程度地减少损耗,线路负荷,以及所需的总无功功率容量。拟定问题是组合问题,因此采用禁忌搜索算法求解优化问题。给出了解决径向33总线配电系统和网状6总线系统的优化问题的结果。当使用较少量的无功容量时,将电压调节器的抽头位置作为控制变量在降低损耗和改善电压曲线方面起着重要作用。在网状系统的情况下,成本函数中包含线路负载会极大地改变解决优化问题的结果,例如所需无功容量的数量以及如何将DG和RS分配给所选总线。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号