Voltage stability is a growing concern for the successful planning and operation of modern power systems. The prediction of voltage collapse point of the multibus power network through its two-bus equivalent model is a hot topic of the research in the field of power system operation and control. This article presents a method to assess the voltage stability status of a power system incorporating the static var compensator (SVC) using a unique two-bus Π-network equivalent model obtained with the optimal power flow solution of the actual system at different operating conditions. The novelty of the proposed methodology is that it considers the series and shunt parts of transmission losses lumped separately in equivalent series and shunt form to evaluate the Π-network equivalent two-bus model. SVC firing angle model is integrated into optimal power flow program to investigate its effect on power system performance in terms of voltage stability assessed in the equivalent two-bus domain. The simulation results for a practical power system (203-bus Indian Eastern Grid) have shown that the proposed methodology is promising to assess voltage stability of any power system at any operating point in global scenario. Voltage stability margin augmentation with the application of SVC at the weakest bus is compared with the system having no compensation. In the proposed Π-network equivalent model, the generators have been modeled more accurately considering economic operation. Copyright © 2011 John Wiley & Sons, Ltd.
机译:电压稳定性已成为现代电力系统成功规划和运行的一个日益关注的问题。通过其两母线等效模型来预测多母线电网的电压崩溃点是电力系统运行与控制领域研究的热点。本文提出了一种方法,该方法使用独特的两母线Π网络等效模型评估结合了静态无功补偿器(SVC)的电力系统的电压稳定性状态,该模型通过实际系统在不同工况下的最佳潮流解决方案获得。所提出方法的新颖之处在于,它考虑了以等效串联和并联形式分别集中的传输损耗的串联和并联部分,以评估Π网络等效两总线模型。将SVC点火角模型集成到最佳潮流程序中,以根据等效两母线域中评估的电压稳定性来研究其对电力系统性能的影响。实际电力系统(203总线的印度东部电网)的仿真结果表明,所提出的方法有望在全球情景下评估任何运行点的任何电力系统的电压稳定性。在没有补偿的情况下,将在最弱的总线上使用SVC的电压稳定裕度提高进行了比较。在提出的Π网络等效模型中,考虑到经济运行,已对发电机进行了更精确的建模。版权所有©2011 John Wiley&Sons,Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号